WB-MAI2-mini / СС

Product is no longer available to order — contact us.
Two-channel analog input module 0-20 mA. Installed injunction boxes and cable channels, connected via Modbus RTU.
Used to connect sensors with 0-20 and 4-20 mA output in dispatch systems for engineering systems and process control.
Main characteristics
Advantages

- You can connect 0-20 mA and 4-20 mA sensors.
- Can be mounted in junction boxes and cable ducts.
- A filter for channels with an adjustable averaging time allows you to filter out sharp current surges caused by interference.
- Can be used with controllers from other manufacturers.
- Wide range of supply voltages (9-28 V).
- Fast and simple integration into the automation and monitoring system.
Hardware

Specifications:
- Power consumption: 0.06 W.
- Number of channels: 2.
- Current measurement: 0-20 mA.
- Input impedance: 49.9 ohms.
- Current measurement error: ±(0.1 mA + 1.5%).
- Supply voltage: 9…28 V.
- Operating temperature: 0…+60 °C.
- Interface: RS-485, Modbus RTU.
- Overall dimensions: 57×18×12 mm.
Quality control at each stage of production

We develop and manufacture all Wiren Board devices ourselves. Also everyone devices undergo multi-stage quality control:
- During development - checking the components used for compliance with the declared ones characteristics and testing of the prototype device at extreme operating conditions.
- After installation of SMD components - automated optical control.
- After soldering the lead components - visual inspection of soldering.
- After assembling the device, functional testing on an automated stand.
- When shipped to the warehouse - control of completeness, stickers, appearance.
Thanks to this approach, the failure rate is no more than 0.5% of all released devices.
If the device fails within two years from the date of purchase, we will replace it for free without need to be sent to a service center.
Setup

When used with a Wiren Board controller, you can use the mouse in the web interface:
- enable or disable input polling,
- adjust the exchange speed.
When used with other equipment, the device can be configured via the RS-485 bus by writing values to Modbus registers. The register table is open, well documented and available on our website.
Reading the readings

If a Wiren Board controller is used, the measured values are available in the controller's web interface and can be used in automation scripts or transferred to a higher-level system. Only the included channels are displayed in the device card.
The module also transmits all data via Modbus RTU (RS-485), which can be read by any equipment or software that supports this protocol: third-party controllers, HMI panels or SCADA.