WB-MAI2-mini / СС v.3

A dual-channel analog input module (0–20 mA). Designed for installation in junction boxes and cable ducts. Communication interface – Modbus RTU.
Used for connecting sensors with interface 0–20 mA and 4–20 mA in dispatching systems for engineering infrastructure and process control systems.
KEY FEATURES
Advantages

- compatible with both 0–20 mA and 4–20 mA sensors
- can be installed in junction boxes and cable ducts
- channel filtering with configurable averaging time to suppress sharp current spikes caused by interference
- compatible with third-party controllers
- wide power supply range: 9…28 V
- quick and easy integration with automation and monitoring systems
- technical support available on the portal
- complete documentation
- optional branding with your company logo
Hardware

Specifications:
- power consumption: 0.06 W
- number of channels: 2
- current measurement range: 0–20 mA
- input resistance: 49.9 Ohm
- current measurement accuracy: ±(0.1 mA + 1.5%)
- power supply voltage: 9…28 V
- operating temperature: −40…+80 °C
- interface: RS-485, Modbus RTU
- dimensions: 34 x 20 x 17 mm
Quality control at each stage of production

We develop and manufacture all Wiren Board devices ourselves. Also everyone devices undergo multi-stage quality control:
- During development - checking the components used for compliance with the declared ones characteristics and testing of the prototype device at extreme operating conditions.
- After installation of SMD components - automated optical control.
- After soldering the lead components - visual inspection of soldering.
- After assembling the device, functional testing on an automated stand.
- When shipped to the warehouse - control of completeness, stickers, appearance.
Thanks to this approach, the failure rate is no more than 0.5% of all released devices.
If the device fails within two years from the date of purchase, we will replace it for free without need to be sent to a service center.
Configuration

When used with a Wiren Board controller, inputs can be enabled or disabled via the web interface with a mouse click.
For configuration without a controller, you can use the Wiren Board Device Editor paired with a WB-USB485 interface converter or a similar device.
When used with third-party equipment, the module can be configured over RS-485 by writing values to Modbus registers. The register table is open, well-documented, and available on our website.
Reading values

If used with a Wiren Board controller, measured values are displayed in the controller’s web interface and can be used in automation scenarios or transferred to a higher-level system. Only enabled channels are shown in the device card.
The module also transmits all data via Modbus RTU (RS-485), which can be read by any device or software that supports this protocol: third-party controllers, HMI panels, or SCADA systems.