'''Warning!''' Numbers used Modbus registers have changed since firmware version '''3.2.0'''. The instructions stated the new numbers of registers. If you are using a device with older firmware, the general principle remains the same, but the numbers of the registers are shifted; as it is — see the [[#Map registers, flags, and inputs (Inputs and Coils)|Map registers, flags, and inputs (Coils and Inputs)]]. A full description of IR device registers can be found in this article under [[#Register map|Register map]].
'''Warning!''' Numbers used Modbus registers have changed since firmware version '''3.2.0'''. The instructions stated the new numbers of registers. If you are using a device with older firmware, the general principle remains the same, but the numbers of the registers are shifted; as it is — see the [[#Map registers, flags, and inputs (Inputs and Coils)|Map registers, flags, and inputs (Coils and Inputs)]]. A full description of IR device registers can be found in this article under [[#Register map|Register map]].


At the physical level, the module is connected via [[RS-485/en| RS-485]]  interface. Modbus RTU Protocol is used to control the devices. In Wiren Board devices, Modbus data is transmitted over RS-485 communication lines. See the [[Протокол Modbus/en|Modbus Protocol]] page for details. Modbus-address of the device is set at the factory and marked on the label. The address can be changed programmatically. Details refer to the [[#Modbus control| Modbus control]].
At the physical level, the module is connected via [[RS-485/en| RS-485]]  interface. Modbus RTU Protocol is used to control the devices. In Wiren Board devices, Modbus data is transmitted over RS-485 communication lines. See the [[Протокол Modbus/en|Modbus Protocol]] page for details. Modbus-address of the device is set at the factory and marked on the label. The address can be changed programmatically.


In devices with firmware version "'3.1.0"' and later it is also possible to change the settings of data exchange parameters — see [[#Register map|Modbus register map]].
In devices with firmware version "'3.1.0"' and later it is also possible to change the settings of data exchange parameters — see [[#Register map|Modbus register map]].
Строка 68: Строка 68:
=== Recording the signal to the RAM from the remote control ===
=== Recording the signal to the RAM from the remote control ===
To write a signal (only one) from the remote control to the RAM without putting it in the ROM - write 1 in the flag register at <code>5001</code>. Further actions occur in the same way as described above to record the signal in ROM. After the recording is stopped in the storage registers at <code>2000</code>, the signal will be stored as a sequence of numbers. You can edit this sequence as described above. Note: the contents of these storage registers are not stored when the device is powered off!
To write a signal (only one) from the remote control to the RAM without putting it in the ROM - write 1 in the flag register at <code>5001</code>. Further actions occur in the same way as described above to record the signal in ROM. After the recording is stopped in the storage registers at <code>2000</code>, the signal will be stored as a sequence of numbers. You can edit this sequence as described above. Note: the contents of these storage registers are not stored when the device is powered off!
= = = = Playing a signal from memory ===
=== Playing a signal from memory ===
To play the signal from memory, write 1 to the flag register at <code>5002</code>. The signal recorded in the storage registers starting with <code>2000</code>will be played. In the absence of the marker of the end of the command will return an error. While the signal is playing, the flag register at <code>5002</code> will be set to 1 and then set to 0. While the signal is being played, no other operations with the IR transceiver via Modbus will be available.
To play the signal from memory, write 1 to the flag register at <code>5002</code>. The signal recorded in the storage registers starting with <code>2000</code>will be played. In the absence of the marker of the end of the command will return an error. While the signal is playing, the flag register at <code>5002</code> will be set to 1 and then set to 0. While the signal is being played, no other operations with the IR transceiver via Modbus will be available.