Строка 70: | Строка 70: | ||
* With Ax terminal controller. Connect one wire to the power supply 5-24V, the second wire to the terminal Ax. | * With Ax terminal controller. Connect one wire to the power supply 5-24V, the second wire to the terminal Ax. | ||
* Using input-output module WBIO-DI-DR-8 (8 channels), see. [[Special: MyLanguage /Модули ввода-вывода| IO Modules ]]. One of the wires connected to GND, the second to terminal Dx of module. | * Using input-output module WBIO-DI-DR-8 (8 channels), see. [[Special: MyLanguage/Модули ввода-вывода | IO Modules ]]. One of the wires connected to GND, the second to terminal Dx of module. | ||
* Using extension module [[Special: MyLanguage/WBE-DI-DR-3 WBE-DI-DR-3]] (3 channels). One of the wires connected to GND, the second terminal of the Ox in the corresponding expansion module. | * Using extension module [[Special: MyLanguage/WBE-DI-DR-3|WBE-DI-DR-3]] (3 channels). One of the wires connected to GND, the second terminal of the Ox in the corresponding expansion module. | ||
* Can be connected to the inputs Rx controller, including internal current source. One of the wires connected to GND, the second to the Rx controller. | * Can be connected to the inputs Rx controller, including internal current source. One of the wires connected to GND, the second to the Rx controller. | ||
Строка 92: | Строка 92: | ||
There are several methods to connect these devices to the controller: | There are several methods to connect these devices to the controller: | ||
* Using input-output module WBIO-DI-DR-8 (8 channels), see. [[Special: MyLanguage / | * Using input-output module WBIO-DI-DR-8 (8 channels), see. [[Special: MyLanguage/Модули ввода-вывода|IO Modules ]]. The output "open collector" connect to terminal Dx module. | ||
* Using extension module [[Special: MyLanguage / WBE-DI-DR-3 | WBE-DI-DR-3]] (3 channels). The output "open collector" connect to terminal Ox corresponding extension module. | * Using extension module [[Special: MyLanguage/WBE-DI-DR-3 |WBE-DI-DR-3]] (3 channels). The output "open collector" connect to terminal Ox corresponding extension module. | ||
* It can be connected to Rx inputs controller, activating the inside current. | * It can be connected to Rx inputs controller, activating the inside current. | ||
Строка 119: | Строка 119: | ||
Ground connect to GND or common ground bus. | Ground connect to GND or common ground bus. | ||
The data line to 1- | The data line to 1-Wire terminal. | ||
The supply line to 5Vout terminal (internal power supply). | The supply line to 5Vout terminal (internal power supply). | ||
It is allowed to use external power supply bus 1-Wire. | It is allowed to use external power supply bus 1-Wire. |