Новая страница: «An adapter with an RJ-12 socket is inserted into the WB-MAP meter instead of a mating terminal block and connected to the transformers with a connecting cable (included). The cable is made of a twisted pair and two 6P6C (RJ-12) plugs crimped in a straight pattern: white-orange, orange, white-green, green, white-blue, blue (see diagram 1).»
(Новая страница: «Step between transformers - 1 DIN module (17.5 mm). It is convenient to install the assembly immediately under the machines. They can also be joined two at a time by turning the right assembly over and crimping the second end of the cable in a different order - this way the step between the transformers will be preserved.! N! It can be attached to the shield panel using self-tapping screws to plastic racks. You can also simply fix it on the cable with ties (...»)
(Новая страница: «An adapter with an RJ-12 socket is inserted into the WB-MAP meter instead of a mating terminal block and connected to the transformers with a connecting cable (included). The cable is made of a twisted pair and two 6P6C (RJ-12) plugs crimped in a straight pattern: white-orange, orange, white-green, green, white-blue, blue (see diagram 1).»)
Строка 49: Строка 49:
Step between transformers - 1 DIN module (17.5 mm). It is convenient to install the assembly immediately under the machines. They can also be joined two at a time by turning the right assembly over and crimping the second end of the cable in a different order - this way the step between the transformers will be preserved.! N! It can be attached to the shield panel using self-tapping screws to plastic racks. You can also simply fix it on the cable with ties (put it on the cable itself to limit the stroke).
Step between transformers - 1 DIN module (17.5 mm). It is convenient to install the assembly immediately under the machines. They can also be joined two at a time by turning the right assembly over and crimping the second end of the cable in a different order - this way the step between the transformers will be preserved.! N! It can be attached to the shield panel using self-tapping screws to plastic racks. You can also simply fix it on the cable with ties (put it on the cable itself to limit the stroke).


<div lang="ru" dir="ltr" class="mw-content-ltr">
An adapter with an RJ-12 socket is inserted into the WB-MAP meter instead of a mating terminal block and connected to the transformers with a connecting cable (included). The cable is made of a twisted pair and two 6P6C (RJ-12) plugs crimped in a straight pattern: white-orange, orange, white-green, green, white-blue, blue (see diagram 1).
Переходник с розеткой RJ-12 вставляется в счетчик WB-MAP вместо ответного клеммника и соединяется с трансформаторами соединительным кабелем (есть в комплекте). Кабель изготовляется из витой пары и двух вилок 6P6C (RJ-12), обжатых по прямой схеме: бело-оранжевый, оранжевый, бело-зеленый, зеленый, бело-синий, синий (см. схему 1).
</div>


<div lang="ru" dir="ltr" class="mw-content-ltr">
<div lang="ru" dir="ltr" class="mw-content-ltr">