Firmware Changelog: различия между версиями

Строка 16: Строка 16:
|
|
|
|
|-
|WB-MS
|28-09-2020
|[http://fw-releases.wirenboard.com/?prefix=fw/by-version/WB-MS/stable/4.15.0/ 4.15.0]
|ALL
|
* Improve input voltage measure and powerdown handle
* Increase software I2C speed to 50 kHz for faster EEPROM writing
* Fixed modbus frame borders detection
* Added holding register 113 to set modbus inter frame timeout
* Rework hdc1080, opt3001, sgpc3 modules with new non blocking i2c library
* Added MSW v3 rev 4.9 target with mems mic and additional highgain adc input channel
* Removed SPL linear approximation calculation. All targets use response tables
* Changed digital input counter saving to EEPROM algorithm for devices with digital inputs. Previously counters data was loaded to EEPROM once per 600 sec. Now if counter increments slower than 1 time per 300s, the data uploads in EEPROM for each change, otherwise, not faster than 1 time per 300s.
|-
|WB-MS
|14-09-2020
|[http://fw-releases.wirenboard.com/?prefix=fw/by-version/WB-MS/stable/4.14.1/ 4.14.1]
|ALL
|Reduce 1wire sensors initialization time.
|-
|-
|WB-MR
|WB-MR
|02-09-2020
|02-09-2020
|[http://fw-releases.wirenboard.com/?prefix=fw/by-version/WB-MR/stable/1.15.1/ 1.15.1]
|[http://fw-releases.wirenboard.com/?prefix=fw/by-version/WB-MR/stable/1.15.1/ 1.15.1]
|ALL
|WB-MIR WB-M1W2 WB-MSv2
|Improve input voltage measure and powerdown handle.
|Improve input voltage measure and powerdown handle.
|-
|-
100

правок