{{warning|1=Starting from firmware version 2.1 to set up counters MAP to web interface using new templates, the name of these devices ends in "'fw2"'. The conversion factor of a number of parameters have changed in such devices. If you select the old template, the current and power will not be displayed correctly. Templates for counters with new firmware are included in the wb-mqtt-serial package starting from version 1.48.}} | {{warning|1=Starting from firmware version 2.1 to set up counters MAP to web interface using new templates, the name of these devices ends in "'fw2"'. The conversion factor of a number of parameters have changed in such devices. If you select the old template, the current and power will not be displayed correctly. Templates for counters with new firmware are included in the wb-mqtt-serial package starting from version 1.48.}} | ||
When you add a WB-MAP12 device, you can choose from several device templates: | |||
{| class="wikitable" | {| class="wikitable" | ||
! | ! Template | ||
! | ! Model and purpose | ||
|- | |- | ||
| WB-MAP12H | | WB-MAP12H | ||
| | | The basic pattern for measurement of the coefficients of the harmonics of current and voltage | ||
|- | |- | ||
| WB-MAP12H (basic) | | WB-MAP12H (basic) | ||
| | | Simplified template for models without measuring current and voltage harmonics (no values of AN, Ifund, N, NN, RN, NP, Pfund, Pharm, S, THD I, THD U, Total AN, Total N, Total Pfund, Total Pharm, Total RN, Total RP, Total S, Total SV, Ufund -- see names on page with list of measured parameters, link above). | ||
|- | |- | ||
| WB-MAP12H (+ harmonics) | | WB-MAP12H (+ harmonics) | ||
| | | Advanced pattern models with the measurement of the coefficients of the harmonics of current and voltage (up to 15 harmonic current and up to 7 harmonics voltage) | ||
|- | |- | ||
| WB-MAP12H (+ all harmonics) | | WB-MAP12H (+ all harmonics) | ||
| | | Complete template for models measuring current and voltage harmonics (up to 42 current and voltage harmonics) | ||
|- | |- | ||
| WB-MAP12H (basic div2) | | WB-MAP12H (basic div2) | ||
| | | Simplified template for models without measuring the coefficients of the harmonics of current and voltage inputs, designed for currents > 65 A | ||
|- | |- | ||
| WB-MAP12E | | WB-MAP12E | ||
| | | Template for models that support the measurement of subsidence of voltage and current (model in development) | ||
|} | |} | ||
== | == Description of Modbus registers == | ||
The meter supports a large number of Modbus registers that store the values of measured and calculated values, as well as counter control registers. | |||
A table of registers describing the measured values can be found on the page [[Power_Meter_Measuring_Registers/en |Power_Meter_Measuring_Registers]]. | |||
Table of control registers is given in the page [[Power_Meter_WB-MAP12H_Control_Registers/en|Power Meter WB-MAP12H Control Registers]]. | |||