Wiren Board 4:Аппаратная часть/en: различия между версиями

Новая страница: «Input stage of Dx channels consists of a circuit for connection of dry contacts. This stage continuously provides 5V voltage at the terminal. In input mode the Tx…»
(Новая страница: «А4 and А5 support binary input function DI: more than 3V at the terminal is considered as triggering of the input.»)
(Новая страница: «Input stage of Dx channels consists of a circuit for connection of dry contacts. This stage continuously provides 5V voltage at the terminal. In input mode the Tx…»)
Строка 219: Строка 219:
А4 and А5 support binary input function DI: more than 3V at the terminal is considered as triggering of the input.
А4 and А5 support binary input function DI: more than 3V at the terminal is considered as triggering of the input.


Для каналов типа Dx входной каскад - это схема для подключения "сухих контактов". Этот каскад постоянно подает напряжение 5В на клемму.
Input stage of Dx channels consists of a circuit for connection of dry contacts. This stage continuously provides 5V voltage at the terminal. In input mode the Tx key is inactive (open). When the terminal is grounded, small current (2 mA) flows via the channel. Controller considers that as triggering of the input. Closing of the Tx key is considered as triggering of the input. In output mode the output stage
В режиме ввода, ключ Tx переводится в неактивное состояние (разомкнут).При замыкании клеммы на 0, через через канал течет небольшой ток (2 ма).  
does not affect the channel operation, provided that a more than 5 V load is connected to the channel.
Это воспринимается контроллером как срабатывание входа.
Замыкание ключа Tx также воспринимается как срабатывание входа.
В режиме вывода входной каскад не влияет на работу канала, при условии что к каналу подключена  нагрузка с напряжением больше 5В.