История
21 марта 2022
Обновление для соответствия новой версии исходной страницы.
+243
Новая страница: «{{DISPLAYTITLE: WB-CT309 Solid-Core Transformers Assembly}}»
−90
Обновление для соответствия новой версии исходной страницы.
+130
20 марта 2022
Новая страница: «== Specifications==»
−93
Новая страница: «If you install two transformer assemblies side by side and turn the second one over, then one of the ends of the cable must be crimped according to a different scheme: orange, white-orange, green, white-green, blue, white-blue (see diagram 2).»
−326
Новая страница: «There are no known faults.»
−160
Новая страница: «70 g |}»
−89
Новая страница: «<gallery widths=260px heights=219px style="clear:both"> Image: Installation WB-CT309.png | Selection of crimping scheme depending on the orientation of the transformer assembly Image: WBCT_RJ12_pinout.png | Scheme 1. Crimping a twisted pair for connecting a transformer assembly. Serial version Image: WBCT_RJ12_pinout invert.png | Scheme 2. Crimping a twisted pair for connecting an '''inverted''' transformer assembly </gallery>»
−322
Новая страница: «== Mounting ==»
−210
Новая страница: «An adapter with an RJ-12 socket is inserted into the WB-MAP meter instead of a mating terminal block and connected to the transformers with a connecting cable (included). The cable is made of a twisted pair and two 6P6C (RJ-12) plugs crimped in a straight pattern: white-orange, orange, white-green, green, white-blue, blue (see diagram 1).»
−292
Новая страница: «Step between transformers - 1 DIN module (17.5 mm). It is convenient to install the assembly immediately under the machines. They can also be joined two at a time by turning the right assembly over and crimping the second end of the cable in a different order - this way the step between the transformers will be preserved.! N! It can be attached to the shield panel using self-tapping screws to plastic racks. You can also simply fix it on the cable with ties (...»
−320
Новая страница: «300px|thumb|right|An example of mounting two assemblies»
−128
Новая страница: «Datasheet for used transformers: File:ZMCT123.pdf»
−98
Новая страница: «{| class="wikitable" style="clear:none" ! style="text-align: center;" | Parameter ! style="text-align: center;" | Value |- |Rated current | 5 A |- |Maximum current | 125 A |- |Hole diameter (max. cable diameter) || 9.5 mm |- |Transformation ratio || 1:2000 |- |Phase angle, 1/1000 of a degree || 120 |- |Dimensions (L x W x H)|| 74 x 30 x 36 mm |-»
−284
Новая страница: «300px|thumb|right|Transformer current measurement error»
−90
Новая страница: «The assembly is intended for use in conjunction with WB-MAP meters as a replacement for split transformers. The use of one-piece transformers is often more convenient and reliable when assembling the shield from scratch.»
−280
Новая страница: «400px|thumb|right|WB-CT309 transformer assembly and WB-MAP meter adapter '''[https://wirenboard.com/en/product/WB-CT309/ Buy online]'''»
+5881