12 063
правки
(Новая страница: «'''[https://wirenboard.com/en/product/WBIO-DI-WD-14/ Buy WBIO-DI-WD-14 online]''' 200px|thumb|right| WBIO-DI-LVD-16») |
(Новая страница: «== Device pictures and drawings == {{WBPicturesNoDrawing|1}}») |
||
(не показано 9 промежуточных версий этого же участника) | |||
Строка 7: | Строка 7: | ||
== | == Purpose == | ||
Input of discrete signals, control of circuit integrity, etc. | |||
== | ==Technical specifications== | ||
Contains 16 inputs to determine the presence of voltage, both alternating (50Hz) and constant voltage of '''both polarities'''. | |||
{| class="wikitable" | {| class="wikitable" | ||
! | !Parameter | ||
! | !Value | ||
|- | |- | ||
| | |Number of inputs | ||
|16 | |16 | ||
|- | |- | ||
| | |Isolated input groups | ||
|2: [1 — 8] и [9 — 16] | |2: [1 — 8] и [9 — 16] | ||
|- | |- | ||
| | |Input type | ||
| | |voltage input | ||
|- | |- | ||
| | |Operating voltage | ||
| | | | ||
* | *detecting signal — >9V AC/DC | ||
* | *no signal <5 V AC/DC | ||
|- | |- | ||
| | |Rated voltage | ||
|12 — 24 | |12 — 24 V AC/DC | ||
|- | |- | ||
| | |Maximum permissible voltage | ||
|50 | |50 V AC/DC | ||
|- | |- | ||
| | |Response time, not more than | ||
|100 | |100 MS | ||
|- | |- | ||
| | |Isolation voltage between input and controller | ||
|5000 | |5000 V (RMS.) | ||
|- | |- | ||
| | |Module type | ||
|I (inverted addr.) | |I (inverted addr.) | ||
|- | |- | ||
| | |Maximum power consumption | ||
|1 | |1 mW | ||
|- | |- | ||
| | |Width, DIN units | ||
|2 | |2 | ||
|- | |- | ||
| | |Size | ||
|53,3 x 90,2 x 57,5 | |53,3 x 90,2 x 57,5 mm | ||
|} | |} | ||
{| class="wikitable" | {| class="wikitable" | ||
!colspan="2" | ''' | !colspan="2" | '''Terminals and wire section''' | ||
|- | |- | ||
|| | || The recommended wire cross section with pin bushing insulated tip, mm<sup>2</sup> || 2,5 | ||
|- | |- | ||
|| | || Standard sleeve length of pin bushing insulated tip, mm || 8 | ||
|- | |- | ||
|| | ||Tightening torque of screws, Н∙м || 0,5 | ||
|- | |- | ||
|} | |} | ||
Строка 71: | Строка 71: | ||
[[File:DIN 3U.png |300px|thumb|right| | [[File:DIN 3U.png |300px|thumb|right|Dimensions]] | ||
== | == Connection to controller == | ||
See section [[Модули_ввода-вывода/en#Activating the modules in the controller web interface|activating the module in the web interface of the controller]]. | |||
== | == Connection == | ||
The voltage is applied to the COM terminal block and to the corresponding module input. The inputs are separated by two isolated terminal groups: | |||
(1,2,3,4,5,6,7,8,COM) | (1,2,3,4,5,6,7,8,COM) and (COM,9,10,11,12,13,14,15,16). Com terminals are common to a group of inputs. | ||
{| class="wikitable" | {| class="wikitable" | ||
|[[ | |[[File:Wbio-di-lvd-16_front_view.png|400px|thumb|right|Wbio-DI-LVD-16 pinout]] | ||
|[[ | |[[File:LVD-2.png|400px|thumb|none|WBIO-DI-LVD module wiring diagram]] | ||
|- | |- | ||
|} | |} | ||
== | == Device pictures and drawings == | ||
{{Wbincludes:WBPicturesNoDrawing|1}} | {{Wbincludes:WBPicturesNoDrawing|1}} |
правки