Only one operation can be performed on only one signal at a time. Since during the execution of any operation one of the registers of flags is set to 1, and after the operation is completed there is set to 0, at any time among all the registers of flags related to the IR transceiver, only one register can be set to one. Attempting to write 1 to IR-related flag registers with an existing unit will result in a <code>BUSY</code> error.
Only one operation can be performed on only one signal at a time. Since during the execution of any operation one of the registers of flags is set to 1, and after the operation is completed there is set to 0, at any time among all the registers of flags related to the IR transceiver, only one register can be set to one. Attempting to write 1 to IR-related flag registers with an existing unit will result in a <code>BUSY</code> error.


== Постоянный режим ==
== Constant mode ==
В постоянном режиме ИК-команды сохраняются в памяти устройства и доступны после перезагрузки по питанию. Каждая команда хранится в отдельном "банке" памяти. Количество банков памяти зависит отпрошивки устройства. До прошивки 3.7.2 включительно устройства имели 7 банков памяти ИК-команд. Начиная с версии 4.4.0 поддерживается 32 банка. Промежуточные версии позволяли записывать до 80 команд, но в ряде случаев делали это некорректно.
In constant mode, the IR commands are stored in the device memory and are available after a power reset. Each command is stored in a separate "Bank" of memory. The number of memory banks depends on the device flashing. Prior to firmware 3.7.2 inclusive, the devices had 7 memory banks of IR commands. Starting with version 4.4.0 32 banks are supported. Intermediate versions allowed to record up to 80 commands, but in some cases did it incorrectly.


==== Запись сигнала в постоянную память с пульта ДУ ====
==== Запись сигнала в постоянную память с пульта ДУ ====