WB-MR3xV and WB-MR6xV Modbus Relay Modules: различия между версиями
Fizikdaos (обсуждение | вклад) |
|||
(не показано 106 промежуточных версий 9 участников) | |||
Строка 1: | Строка 1: | ||
{{ | <languages/> | ||
== | <translate> | ||
<!--T:1--> | |||
{{#vardefine:ProductFullName1|Релейный модуль WB-MR3HV/I}} {{#vardefine:FileName1|WB-MR3HV_I}} {{#vardefine:ProductName1|WB-MR3HV/I}} {{#vardefine:ProductFullName2|Релейный модуль WB-MR3HV/S}} {{#vardefine:FileName2|WB-MR3HV_S}} {{#vardefine:ProductName2|WB-MR3HV/S}} {{#vardefine:ProductFullName3|Релейный модуль WB-MR3LV/I}} {{#vardefine:FileName3|WB-MR3LV_I}} {{#vardefine:ProductName3|WB-MR3LV/I}} {{#vardefine:ProductFullName4|Релейный модуль WB-MR3LV/S}} {{#vardefine:FileName4|WB-MR3LV_S}} {{#vardefine:ProductName4|WB-MR3LV/S}} {{#vardefine:ProductFullName5|Релейный модуль WB-MR6HV/I}} {{#vardefine:FileName5|WB-MR6HV_I}} {{#vardefine:ProductName5|WB-MR6HV/I}} {{#vardefine:ProductFullName6|Релейный модуль WB-MR6HV/S}} {{#vardefine:FileName6|WB-MR6HV_S}} {{#vardefine:ProductName6|WB-MR6HV/S}} {{#vardefine:ProductFullName7|Релейный модуль WB-MR6LV/I}} {{#vardefine:FileName7|WB-MR6LV_I}} {{#vardefine:ProductName7|WB-MR6LV/I}} {{#vardefine:ProductFullName8|Релейный модуль WB-MR6LV/S}}{{#vardefine:FileName8|WB-MR6LV_S}} {{#vardefine:ProductName8|WB-MR6LV/S}} | |||
'''[https://wirenboard.com/ru/product/WB-MR3/ Купить WB-MR3xV в интернет-магазине]''' | |||
'''[https://wirenboard.com/ru/product/WB-MR6/ Купить WB-MR6xV в интернет-магазине]''' | |||
[[File:MR3MR6.jpg |600px|thumb|right| Релейные модули в модификациях MR3HV/I и MR6HV/I]] | |||
== Назначение== | |||
Трех- и шестиканальные модули реле серий WB-MR3xV и WB-MR6xV предназначены для систем промышленной и домашней автоматизации. | |||
Предназначены для коммутирования силовой нагрузки общего назначения, в т.ч. с большими пусковыми токами: управления светодиодными светильниками, лампами накаливания, импульсными блоками питания и т.п. | |||
<!--T:2--> | |||
Модули рассчитаны на нагрузку 16А (номинал 10А) и могут использоваться без промежуточных контакторов, предусмотрен вход, одновременно отключающий всю нагрузку. | |||
=== Схема наименования === <!--T:3--> | |||
<!--T:4--> | |||
WB-MR '''N XX''' / '''Y''', где: | |||
'''N''' - количество каналов (3 или 6). | |||
'''XX''' - тип входов (LV -"сухой контакт" или HV - входы 230V AC). | |||
'''Y''' - тип реле (I или S) | |||
Например WB-MR3LV/S - три канала, тип входа "сухой контакт", реле с сверхбольшим пусковым током. | |||
<!--T:5--> | |||
Схема наименования: | |||
{| class="wikitable" | |||
!WB-MR | |||
!N | |||
! | |||
! colspan="2" |XX | |||
!/ | |||
! colspan="2" |YY | |||
|- | |||
| rowspan="4" | | |||
|'''Каналы''' | |||
| | |||
| colspan="2" |'''Тип входов''' | |||
| | |||
| colspan="2" |'''Тип релейных выходов''' | |||
|- | |||
| rowspan="3" |'''3 или 6''' | |||
| | |||
|'''LV''' | |||
|входы для сигналов "сухой контакт" ('''L'''ow '''V'''oltage) | |||
| | |||
|'''I''' | |||
|конфигурация SPDT, нормально открытый/нормально закрытый контакты), большой пусковой ток ('''I''') | |||
|- | |||
| | |||
|'''HV''' | |||
|входы 230V AC ('''H'''igh '''V'''oltage) | |||
| | |||
|'''S''' | |||
|конфигурация SPST (нормально открытый контакт), сверхвысокий пусковой ток, | |||
реле с контактами специальной конструкции ('''S''') (в материал контактов входит вольфрам) | |||
|- | |||
| | |||
| | |||
| | |||
| | |||
|'''R''' | |||
|(конфигурация SPDT, нормально отркрытый/нормально закрытый контакты), | |||
для резистивной нагрузки ('''R''') (поставляется по заказу) | |||
|} | |||
== Технические характеристики == <!--T:15--> | |||
<!--T:16--> | |||
{| border="1" class="wikitable" style="text-align:left" | |||
|- | |||
!Параметр | |||
!Значение | |||
|- | |||
! colspan="2" |Питание | |||
|- | |||
|Напряжение питания | |||
|9 — 28 В постоянного тока | |||
|- | |||
|Потребляемая мощность | |||
| | |||
*В режиме холостого хода (со всеми выключенными реле) — 0,5 Вт | |||
*Со всеми включенными реле — WB-MR3xV: 1,5 Вт; WB-MR6xV: 3 Вт | |||
*Пиковое значение — до 8 Вт в течение 20 мс | |||
|- | |||
! colspan="2" |'''Выходы''' | |||
|- | |||
|Тип выходов | |||
|Контакты механического реле | |||
|-|- | |||
|Конфигурация выходов | |||
|3 или 6 выходов, соединенных с контактами реле | |||
|- | |||
|Конфигурация контактов каждого выхода | |||
|Двухпозиционные, нормально открытые в модификации '''S''' (С и NO) | |||
Двухпозиционные с переключением в модификациях '''I''' и '''R''' (NC C NO) | |||
|- | |||
|Максимальное коммутируемое напряжение, AC | |||
|250 В | |||
|- | |||
|Максимальное коммутируемое напряжение, DC | |||
|30 В | |||
|- | |||
|Максимальный коммутируемый ток | |||
| | |||
см. таблицу в разделе [[#Параметры реле|#Параметры реле]] | |||
|- | |||
|Сопротивление контактов | |||
|< 100 миллиом | |||
|- | |||
|Напряжение изоляции между контроллером и выходом | |||
|5000 Vrms | |||
|- | |||
|Срок жизни: | |||
|см. таблицу в разделе [[#Параметры реле|#Параметры реле]] | |||
|- | |||
{{:Includes. Relay}} | |||
{{:Includes. Klemmy}} | |||
! colspan="2" |Габариты | |||
|- | |||
|Ширина, DIN-юнитов | |||
|3/6 | |||
|- | |||
|Габаритные размеры (Д x Ш х В) | |||
|WB-MR3xV: 53,3 x 90,2 x 57,5 мм | |||
WB-MR6xV: 106,25 x 90,2 x 57,5 мм | |||
|- | |||
|} | |||
== Общий принцип работы == | |||
== Монтаж модулей типа WB-MR3xV and WB-MR6xV == <!--T:20--> | |||
[[File:Installation_WB3_+_WB5_+_DIN.png|600px|thumb|right|Образец монтажа и подключения модуля WB-MR3HV/I. Выбор качественного блока питания очень важен для работы устройства. Кнопка с проводами желтого цвета, подключенная ко входу "4", отключает все три канала одновременно.]] | |||
[[File:Installation_WB_MR6LV+WB5.png|600px|thumb|right|Образец монтажа и подключения модуля WB-MR6HV/I. Выбор качественного блока питания очень важен для работы устройства. Кнопка с проводами желтого цвета, подключенная ко входу "7", отключает все шесть каналов одновременно.]] | |||
{{:Includes. Mount Relay}} | |||
'''Входы HV высокоимпедансные - возможно ложное срабатывание от наводок на длинных кабелях.''' | |||
Если длина кабеля >10 метров, в кабеле должна быть с нейтраль N или земля PE - это снижает наводки на сигнальный провод. | |||
== Режим работы реле в случае отключении питания == <!--T:29--> | |||
<!--T:30--> | |||
В зависимости от значения, записанного в регистр хранения 0x06, после отключения и восстановления питания модуля реле останутся выключенными (если значение — 0, или включатся те, которые были включены до перерыва в питании, если в регистре записано значение 1). Этот функционал появился в модулях с прошивкой, начиная с версии 1.5.3. | |||
== Управление по Modbus == <!--T:31--> | |||
<!--T:32--> | |||
Подробно о работе с устройством по протоколу Modbus написано в разделе [[Relay Module Modbus Management|Управление модулями реле Wirenboard по протоколу Modbus]]. | |||
Там же можно найти карту регистров устройства. | |||
== Идентификация устройства по Modbus == | |||
Модель устройства и сигнатура прошивки для WB-MR3XX/X | |||
{| border="1" class="wikitable" style="text-align:center; width:1000px;" | |||
!Регистр / адрес | |||
!Тип | |||
!Чтение/запись | |||
!Значение по умолчанию | |||
!Диапазон значений | |||
!Назначение | |||
|- | |||
| 200-206 || input || R || WBMR3 || строка, null-terminated || модель устройства | |||
|- | |||
| 290-302 || input || R || mr3 || строка, null-terminated || сигнатура прошивки | |||
|- | |||
|} | |||
Модель устройства и сигнатура прошивки для WB-MR6XX/X | |||
{| border="1" class="wikitable" style="text-align:center; width:1000px;" | |||
!Регистр / адрес | |||
!Тип | |||
!Чтение/запись | |||
!Значение по умолчанию | |||
!Диапазон значений | |||
!Назначение | |||
|- | |||
| 200-206 || input || R || WBMR6 || строка, null-terminated || модель устройства | |||
|- | |||
| 290-302 || input || R || mr6 || строка, null-terminated || сигнатура прошивки | |||
|- | |||
|} | |||
== Обновление прошивки устройства == | |||
Начиная с новых версий микропрограмм устройства поддерживается функционал обновления прошивки (микропрограммы) по протоколу Modbus. Это дает возможность расширять функциональные возможности устройств и устранять ошибки в микропрограммном обеспечении непосредственно на месте монтажа. Подробнее о перепрошивке устройств рассказано в статье [[WB-MCU-Flasher|Загрузка прошивок на устройства Wiren Board]]. Список версий прошивок, поддерживающих обновление, а также устройств, для которых эта функция реализована, можно найти в статье [[Firmware_Changelog]]. | |||
== Ревизии устройства == | |||
Ревизия устройства указана на наклейке на боковой поверхности корпуса, а также на печатной плате. | |||
WB-MR6LV | |||
{| class="wikitable" | |||
!Ревизия | |||
!Партии | |||
!Дата выпуска | |||
!Отличия от предыдущей ревизии | |||
|- | |||
|3.3 | |||
| v3.3E - ... | |||
|11.2019 | |||
| | |||
* Напряжение на входах типа "сухой контакт" стало ~12B | |||
* Увеличена максимальная частота работы входов до 1 кГц (для прошивок начиная с 1.13.0) | |||
|- | |||
|3.3 | |||
|3.3A - 3.3C | |||
| до 11.2019 | |||
| | |||
*Напряжение на входах типа "сухой контакт" ~4,5B | |||
|- | |||
|} | |||
WB-MR3LV | |||
{| class="wikitable" | |||
!Ревизия | |||
!Партии | |||
!Дата выпуска | |||
!Отличия от предыдущей ревизии | |||
|- | |||
|3.3 | |||
| 3.3A - .. | |||
|12.2019 | |||
| | |||
* Напряжение на входах типа "сухой контакт" стало ~12B | |||
* Увеличена максимальная частота работы входов до 1 кГц (для прошивок начиная с 1.13.0) | |||
|- | |||
|3.1 | |||
|3.1A - 3.1B | |||
| до 11.2019 | |||
| | |||
*Напряжение на входах типа "сухой контакт" ~4,5B | |||
|- | |||
|} | |||
== Известные неисправности == | |||
[[WB-MR:_Errata |Список известных неисправностей]] | |||
== Изображения и чертежи устройства == | |||
По ссылкам ниже вы можете скачать изображения и чертежи моделей. | |||
{| class="wikitable" | |||
|- | |||
| [[File:DIN 6U.png |300px|thumb|right|]] | |||
| [[File:DIN 3U.png |400px|thumb|right|]] | |||
|} | |||
{| class="wikitable" | |||
! Модель !! CorelDRAW !! PDF CorelDRAW !! Autocad 2013 DXF !! Autocad PDF | |||
|- | |||
! {{#var:ProductName1}} | |||
| [[Media:{{#var:FileName1}}.cdr.zip|{{#var:FileName1}}.cdr.zip]] || [[Media:{{#var:FileName1}}.cdr.pdf|{{#var:FileName1}}.cdr.pdf]] || [[Media:{{#var:FileName1}}.dxf.zip|{{#var:FileName1}}.dxf.zip]] || [[Media:{{#var:FileName1}}.pdf|{{#var:FileName1}}.pdf]] | |||
|- | |||
! {{#var:ProductName2}} | |||
| [[Media:{{#var:FileName2}}.cdr.zip|{{#var:FileName2}}.cdr.zip]] || [[Media:{{#var:FileName2}}.cdr.pdf|{{#var:FileName2}}.cdr.pdf]] || [[Media:{{#var:FileName2}}.dxf.zip|{{#var:FileName2}}.dxf.zip]] || [[Media:{{#var:FileName2}}.pdf|{{#var:FileName2}}.pdf]] | |||
|- | |||
! {{#var:ProductName3}} | |||
| [[Media:{{#var:FileName3}}.cdr.zip|{{#var:FileName3}}.cdr.zip]] || [[Media:{{#var:FileName3}}.cdr.pdf|{{#var:FileName3}}.cdr.pdf]] || [[Media:{{#var:FileName3}}.dxf.zip|{{#var:FileName3}}.dxf.zip]] || [[Media:{{#var:FileName3}}.pdf|{{#var:FileName3}}.pdf]] | |||
|- | |||
! {{#var:ProductName4}} | |||
| [[Media:{{#var:FileName4}}.cdr.zip|{{#var:FileName4}}.cdr.zip]] || [[Media:{{#var:FileName4}}.cdr.pdf|{{#var:FileName4}}.cdr.pdf]] || [[Media:{{#var:FileName4}}.dxf.zip|{{#var:FileName4}}.dxf.zip]] || [[Media:{{#var:FileName4}}.pdf|{{#var:FileName4}}.pdf]] | |||
|} | |||
{| class="wikitable" | |||
! Модель !! CorelDRAW !! PDF CorelDRAW !! Autocad 2013 DXF !! Autocad PDF | |||
|- | |||
! {{#var:ProductName5}} | |||
| [[Media:{{#var:FileName5}}.cdr.zip|{{#var:FileName5}}.cdr.zip]] || [[Media:{{#var:FileName5}}.cdr.pdf|{{#var:FileName5}}.cdr.pdf]] || [[Media:{{#var:FileName5}}.dxf.zip|{{#var:FileName5}}.dxf.zip]] || [[Media:{{#var:FileName5}}.pdf|{{#var:FileName5}}.pdf]] | |||
|- | |||
! {{#var:ProductName6}} | |||
| [[Media:{{#var:FileName6}}.cdr.zip|{{#var:FileName6}}.cdr.zip]] || [[Media:{{#var:FileName6}}.cdr.pdf|{{#var:FileName6}}.cdr.pdf]] || [[Media:{{#var:FileName6}}.dxf.zip|{{#var:FileName6}}.dxf.zip]] || [[Media:{{#var:FileName6}}.pdf|{{#var:FileName6}}.pdf]] | |||
|- | |||
! {{#var:ProductName7}} | |||
| [[Media:{{#var:FileName7}}.cdr.zip|{{#var:FileName7}}.cdr.zip]] || [[Media:{{#var:FileName7}}.cdr.pdf|{{#var:FileName7}}.cdr.pdf]] || [[Media:{{#var:FileName6}}.dxf.zip|{{#var:FileName7}}.dxf.zip]] || [[Media:{{#var:FileName7}}.pdf|{{#var:FileName7}}.pdf]] | |||
|- | |||
! {{#var:ProductName8}} | |||
| [[Media:{{#var:FileName8}}.cdr.zip|{{#var:FileName8}}.cdr.zip]] || [[Media:{{#var:FileName8}}.cdr.pdf|{{#var:FileName8}}.cdr.pdf]] || [[Media:{{#var:FileName8}}.dxf.zip|{{#var:FileName8}}.dxf.zip]] || [[Media:{{#var:FileName8}}.pdf|{{#var:FileName8}}.pdf]] | |||
|} | |||
</translate> |
Версия 16:47, 24 апреля 2020
Купить WB-MR3xV в интернет-магазине
Купить WB-MR6xV в интернет-магазине
Назначение
Трех- и шестиканальные модули реле серий WB-MR3xV и WB-MR6xV предназначены для систем промышленной и домашней автоматизации. Предназначены для коммутирования силовой нагрузки общего назначения, в т.ч. с большими пусковыми токами: управления светодиодными светильниками, лампами накаливания, импульсными блоками питания и т.п.
Модули рассчитаны на нагрузку 16А (номинал 10А) и могут использоваться без промежуточных контакторов, предусмотрен вход, одновременно отключающий всю нагрузку.
Схема наименования
WB-MR N XX / Y, где:
N - количество каналов (3 или 6).
XX - тип входов (LV -"сухой контакт" или HV - входы 230V AC).
Y - тип реле (I или S)
Например WB-MR3LV/S - три канала, тип входа "сухой контакт", реле с сверхбольшим пусковым током.
Схема наименования:
WB-MR | N | XX | / | YY | |||
---|---|---|---|---|---|---|---|
Каналы | Тип входов | Тип релейных выходов | |||||
3 или 6 | LV | входы для сигналов "сухой контакт" (Low Voltage) | I | конфигурация SPDT, нормально открытый/нормально закрытый контакты), большой пусковой ток (I) | |||
HV | входы 230V AC (High Voltage) | S | конфигурация SPST (нормально открытый контакт), сверхвысокий пусковой ток,
реле с контактами специальной конструкции (S) (в материал контактов входит вольфрам) | ||||
R | (конфигурация SPDT, нормально отркрытый/нормально закрытый контакты),
для резистивной нагрузки (R) (поставляется по заказу) |
Технические характеристики
Includes. RelayПараметр | Значение |
---|---|
Питание | |
Напряжение питания | 9 — 28 В постоянного тока |
Потребляемая мощность |
|
Выходы | |
Тип выходов | Контакты механического реле |
Конфигурация выходов | 3 или 6 выходов, соединенных с контактами реле |
Конфигурация контактов каждого выхода | Двухпозиционные, нормально открытые в модификации S (С и NO)
Двухпозиционные с переключением в модификациях I и R (NC C NO) |
Максимальное коммутируемое напряжение, AC | 250 В |
Максимальное коммутируемое напряжение, DC | 30 В |
Максимальный коммутируемый ток |
см. таблицу в разделе #Параметры реле |
Сопротивление контактов | < 100 миллиом |
Напряжение изоляции между контроллером и выходом | 5000 Vrms |
Срок жизни: | см. таблицу в разделе #Параметры реле |
Клеммники и сечение проводов | |
Рекомендуемое сечение провода с НШВИ | 0,75 — 1 мм2 для входов управления, 2,5 мм2 — для силовых входов |
Длина стандартной втулки НШВИ | 8 мм |
Момент затяжки винтов | 0,2 Н∙м для входов управления, 0,5 Н∙м — для силовых выходов |
Габариты | |
Ширина, DIN-юнитов | 3/6 |
Габаритные размеры (Д x Ш х В) | WB-MR3xV: 53,3 x 90,2 x 57,5 мм
WB-MR6xV: 106,25 x 90,2 x 57,5 мм |
Общий принцип работы
Монтаж модулей типа WB-MR3xV and WB-MR6xV
Устройство монтируется на стандартную DIN-рейку шириной 35 мм. Клеммный блок «V+ GND A B» с шагом 3.5 мм служит для подключения питания и управления по шине RS-485. Для стабильной связи с устройством важно правильно организовать подключение к шине RS-485, читайте об этом в статье Физическое подключение шины RS-485.
Если устройства, подключенные к шине RS-485, питаются от разных источников питания, их клеммы GND должны быть соединены, подробнее в статье Заземление устройств Wiren Board и подключение контактов GND и iGND.
При включении реле, модуль импульсно потребляет большую мощность (см. потребление). Используйте блок питания с запасом по мощности.
Срабатывание дискретных входов происходит при их замыкании на землю iGND. Возникающий ток невелик (~2 мА), так что тип кнопки или выключателя может быть любым. Также не играет роли длина и сечение кабеля. Но для предотвращения наводок от близко расположенных силовых линий лучше использовать витую пару и подключать землю iGND ко второй жиле пары. Подробнее про подключение клемм iGND/GND.
Сечение проводов, подключаемых к винтовым зажимам выходов реле, должны соответствовать мощности коммутируемой нагрузки. Винтовые зажимы принимают провод сечением 2,5—4 мм2. Модуль реле необходимо устанавливать таким образом, чтобы удовлетворять требованиям электробезопасности и не допускать случайного касания контактов, находящихся под высоким напряжением. Устройство должно эксплуатироваться при рекомендованных условиях окружающей среды.
Входы HV высокоимпедансные - возможно ложное срабатывание от наводок на длинных кабелях.
Если длина кабеля >10 метров, в кабеле должна быть с нейтраль N или земля PE - это снижает наводки на сигнальный провод.
Режим работы реле в случае отключении питания
В зависимости от значения, записанного в регистр хранения 0x06, после отключения и восстановления питания модуля реле останутся выключенными (если значение — 0, или включатся те, которые были включены до перерыва в питании, если в регистре записано значение 1). Этот функционал появился в модулях с прошивкой, начиная с версии 1.5.3.
Управление по Modbus
Подробно о работе с устройством по протоколу Modbus написано в разделе Управление модулями реле Wirenboard по протоколу Modbus. Там же можно найти карту регистров устройства.
Идентификация устройства по Modbus
Модель устройства и сигнатура прошивки для WB-MR3XX/X
Регистр / адрес | Тип | Чтение/запись | Значение по умолчанию | Диапазон значений | Назначение |
---|---|---|---|---|---|
200-206 | input | R | WBMR3 | строка, null-terminated | модель устройства |
290-302 | input | R | mr3 | строка, null-terminated | сигнатура прошивки |
Модель устройства и сигнатура прошивки для WB-MR6XX/X
Регистр / адрес | Тип | Чтение/запись | Значение по умолчанию | Диапазон значений | Назначение |
---|---|---|---|---|---|
200-206 | input | R | WBMR6 | строка, null-terminated | модель устройства |
290-302 | input | R | mr6 | строка, null-terminated | сигнатура прошивки |
Обновление прошивки устройства
Начиная с новых версий микропрограмм устройства поддерживается функционал обновления прошивки (микропрограммы) по протоколу Modbus. Это дает возможность расширять функциональные возможности устройств и устранять ошибки в микропрограммном обеспечении непосредственно на месте монтажа. Подробнее о перепрошивке устройств рассказано в статье Загрузка прошивок на устройства Wiren Board. Список версий прошивок, поддерживающих обновление, а также устройств, для которых эта функция реализована, можно найти в статье Firmware_Changelog.
Ревизии устройства
Ревизия устройства указана на наклейке на боковой поверхности корпуса, а также на печатной плате.
WB-MR6LV
Ревизия | Партии | Дата выпуска | Отличия от предыдущей ревизии |
---|---|---|---|
3.3 | v3.3E - ... | 11.2019 |
|
3.3 | 3.3A - 3.3C | до 11.2019 |
|
WB-MR3LV
Ревизия | Партии | Дата выпуска | Отличия от предыдущей ревизии |
---|---|---|---|
3.3 | 3.3A - .. | 12.2019 |
|
3.1 | 3.1A - 3.1B | до 11.2019 |
|
Известные неисправности
Список известных неисправностей
Изображения и чертежи устройства
По ссылкам ниже вы можете скачать изображения и чертежи моделей.
Модель | CorelDRAW | PDF CorelDRAW | Autocad 2013 DXF | Autocad PDF |
---|---|---|---|---|
WB-MR3HV/I | WB-MR3HV_I.cdr.zip | WB-MR3HV_I.cdr.pdf | WB-MR3HV_I.dxf.zip | WB-MR3HV_I.pdf |
WB-MR3HV/S | WB-MR3HV_S.cdr.zip | WB-MR3HV_S.cdr.pdf | WB-MR3HV_S.dxf.zip | WB-MR3HV_S.pdf |
WB-MR3LV/I | WB-MR3LV_I.cdr.zip | WB-MR3LV_I.cdr.pdf | WB-MR3LV_I.dxf.zip | WB-MR3LV_I.pdf |
WB-MR3LV/S | WB-MR3LV_S.cdr.zip | WB-MR3LV_S.cdr.pdf | WB-MR3LV_S.dxf.zip | WB-MR3LV_S.pdf |
Модель | CorelDRAW | PDF CorelDRAW | Autocad 2013 DXF | Autocad PDF |
---|---|---|---|---|
WB-MR6HV/I | WB-MR6HV_I.cdr.zip | WB-MR6HV_I.cdr.pdf | WB-MR6HV_I.dxf.zip | WB-MR6HV_I.pdf |
WB-MR6HV/S | WB-MR6HV_S.cdr.zip | WB-MR6HV_S.cdr.pdf | WB-MR6HV_S.dxf.zip | WB-MR6HV_S.pdf |
WB-MR6LV/I | WB-MR6LV_I.cdr.zip | WB-MR6LV_I.cdr.pdf | WB-MR6LV_I.dxf.zip | WB-MR6LV_I.pdf |
WB-MR6LV/S | WB-MR6LV_S.cdr.zip | WB-MR6LV_S.cdr.pdf | WB-MR6LV_S.dxf.zip | WB-MR6LV_S.pdf |