Перейти к содержанию

Навигация

WB-MRM2-mini Modbus Relay Modules/en: различия между версиями

Часть переводимой страницы WB-MRM2-mini.
(Часть переводимой страницы WB-MRM2-mini.)
 
(не показано 9 промежуточных версий 2 участников)
Строка 2: Строка 2:
{{DISPLAYTITLE:Dual Channel Relay Mini-module WB-MRM2-mini}}{{#vardefine:ProductFullName1|Dual Channel Relay Mini-module WB-MRM2-mini NO}} {{#vardefine:FileName1|WB_MRM2-mini_NO}} {{#vardefine:ProductName1|WB_MRM2-mini_NO}} {{#vardefine:ProductFullName2|Dual Channel Relay Mini-module WB-MRM2-mini NC}} {{#vardefine:FileName2|WB_MRM2-mini_NC}} {{#vardefine:ProductName2|WB_MRM2-mini_NC}}
{{DISPLAYTITLE:Dual Channel Relay Mini-module WB-MRM2-mini}}{{#vardefine:ProductFullName1|Dual Channel Relay Mini-module WB-MRM2-mini NO}} {{#vardefine:FileName1|WB_MRM2-mini_NO}} {{#vardefine:ProductName1|WB_MRM2-mini_NO}} {{#vardefine:ProductFullName2|Dual Channel Relay Mini-module WB-MRM2-mini NC}} {{#vardefine:FileName2|WB_MRM2-mini_NC}} {{#vardefine:ProductName2|WB_MRM2-mini_NC}}
'''[https://wirenboard.com/en/product/WB-MRM2-mini/ Buy online]'''
'''[https://wirenboard.com/en/product/WB-MRM2-mini/ Buy online]'''
[[File:MiniRelay-2.JPG| thumb | 200px|Dual Channel Relay Mini-module WB-MRM2-mini]]
[[File:MINI.png| thumb | 200px|Dual Channel Relay Mini-module WB-MRM2-mini v.2]]
[[File:Mrm-2-mini_.png| thumb | 200px|Dual Channel Relay Mini-module WB-MRM2-mini]]
[[File:MiniRelay-2.JPG| thumb | 200px|Dual Channel Relay Mini-module WB-MRM2-mini v.1]]
 


== General information ==
== General information ==
=== Purpose===  
=== Purpose===  
Two-channel relay module WB-MRM2-mini is designed for use in building automation systems. The module is controlled from the controller [[Wiren Board 6/en|Wiren Board 6]] or a computer via the bus [[RS-485/en| RS-485]] via [[Relay Module Modbus Management/en |Modbus Protocol]], as well as via external buttons connected to the module. Miniature dimensions of the module allow you to mount it next to the load in the cable channels, bowls lamps, deep installation boxes for sockets and switches.
Two-channel relay module WB-MRM2-mini v.2 is designed for use in building automation systems. The WB-MRM2-mini v.1 featured all-in-one terminal blocks and a lower height (46 mm). The module is mnaged from the controller [[Wiren Board 6/en|Wiren Board 6]] or a computer via the bus [[RS-485/en| RS-485]] via [[Relay Module Modbus Management/en |Modbus Protocol]], as well as via external buttons connected to the module. Miniature dimensions of the module allow you to mount it next to the load in the cable channels, bowls lamps, deep installation boxes for sockets and switches.


=== Outputs===   
=== Outputs===   
Строка 128: Строка 129:
|-
|-
|Overall dimensions (l x W x h)  
|Overall dimensions (l x W x h)  
|46 x 24 x 20.5 mm
|52 x 24 x 20.5 mm
|-
|-
! colspan="2" |Display
! colspan="2" |Display
Строка 150: Строка 151:


===Module dimensions ===
===Module dimensions ===
[[File:Wb-mrm2-mini-sketch.png|400px|thumb|left
[[File:Wb-mrm2-mini-scetch.png|400px|thumb|left
|Module dimensions WB-MRM2-mini]]
|Module dimensions WB-MRM2-mini]]


Строка 187: Строка 188:
== Module Control via the Wiren Board web interface ==
== Module Control via the Wiren Board web interface ==


An example of controlling a WB-MRM2-mini relay module with a Wiren Board 5 controller and programming control scenarios will be discussed in a simple layout, where the relay module is the only device connected to the controller (see the diagram in [[#Mounting|Mounting]]). Normally open button without fixation is connected to input 1 and GND. 12 V power is supplied to the V+(+) and GND (- ) inputs. The RS-485 A and B inputs/outputs of the first controller port and the WB-MRM2-mini module are connected.  
An example of controlling a WB-MRM2-mini relay module with a Wiren Board 6 controller and programming control scenarios will be discussed in a simple layout, where the relay module is the only device connected to the controller (see the diagram in [[#Mounting|Mounting]]). Normally open button without fixation is connected to input 1 and GND. 12 V power is supplied to the V+(+) and GND (- ) inputs. The RS-485 A and B inputs/outputs of the first controller port and the WB-MRM2-mini module are connected.  


{|  border="0" class="wikitable" style="text-align:center; float:right; margin-left: 10px;"
{|  border="0" class="wikitable" style="text-align:center; float:right; margin-left: 10px;"
wb_editors
14 355

правок