Fizikdaos (обсуждение | вклад) (Новая страница: «And a controller '' 'to have a common ground' ''. There are several methods to connect these devices to the controller:») |
FuzzyBot (обсуждение | вклад) м (FuzzyBot переименовал страницу Connecting peripheral devices/en в Using Wiren Board with peripheral devices/en без оставления перенаправления: Часть переводимой страницы Connecting peripheral devices.) |
||
(не показаны 32 промежуточные версии 3 участников) | |||
Строка 19: | Строка 19: | ||
For overvoltage protection controller integrated protective diodes - external protective elements are not required. | For overvoltage protection controller integrated protective diodes - external protective elements are not required. | ||
Also for low-voltage load switching, you can use digital output module (WBIO-DO-HS-8), see. [[Special: MyLanguage / | Also for low-voltage load switching, you can use digital output module (WBIO-DO-HS-8), see. [[Special:MyLanguage/Модули ввода-вывода| Modules IO]]. | ||
Строка 43: | Строка 43: | ||
Also for the connection of current sensors designed special [[Wiren Board 5: Модуль расширения ADC | extension module]]. | Also for the connection of current sensors designed special [[Special:MyLanguage/Wiren Board 5: Модуль расширения ADC | extension module]]. | ||
Строка 56: | Строка 56: | ||
For a more accurate measurement of resistance, as well as to connect Pt100, Pt1000 and for two- and three-wire circuit | For a more accurate measurement of resistance, as well as to connect Pt100, Pt1000 and for two- and three-wire circuit | ||
is a special [[Wiren Board 5: | is a special [[Special:MyLanguage/Wiren Board 5: Модуль расширения ADC| extension module]]. | ||
Строка 70: | Строка 70: | ||
* With Ax terminal controller. Connect one wire to the power supply 5-24V, the second wire to the terminal Ax. | * With Ax terminal controller. Connect one wire to the power supply 5-24V, the second wire to the terminal Ax. | ||
* Using input-output module WBIO-DI-DR-8 (8 channels), see. [[Special: MyLanguage / | * Using input-output module WBIO-DI-DR-8 (8 channels), see. [[Special: MyLanguage/Модули ввода-вывода | IO Modules ]]. One of the wires connected to GND, the second to terminal Dx of module. | ||
* Using extension module [[Special: MyLanguage / WBE-DI-DR-3 | WBE-DI-DR-3]] (3 channels). One of the wires connected to GND, the second terminal of the Ox in the corresponding expansion module. | * Using extension module [[Special: MyLanguage/WBE-DI-DR-3|WBE-DI-DR-3]] (3 channels). One of the wires connected to GND, the second terminal of the Ox in the corresponding expansion module. | ||
* Can be connected to the inputs Rx controller, including internal current source. One of the wires connected to GND, the second to the Rx controller. | * Can be connected to the inputs Rx controller, including internal current source. One of the wires connected to GND, the second to the Rx controller. | ||
Строка 92: | Строка 92: | ||
There are several methods to connect these devices to the controller: | There are several methods to connect these devices to the controller: | ||
* | * Using input-output module WBIO-DI-DR-8 (8 channels), see. [[Special: MyLanguage/Модули ввода-вывода|IO Modules ]]. The output "open collector" connect to terminal Dx module. | ||
* | * Using extension module [[Special: MyLanguage/WBE-DI-DR-3 |WBE-DI-DR-3]] (3 channels). The output "open collector" connect to terminal Ox corresponding extension module. | ||
* | * It can be connected to Rx inputs controller, activating the inside current. | ||
== | == Contactors with a 110/250V control voltage == | ||
Use the extension module with relay outputs, eg[[Special:MyLanguage/Модули ввода-вывода#Модуль релейных выходов (WBIO-DO-R3A-8)|WBIO-DO-R3A-8]]. | |||
Connect the control contactor coil through the relay extension module (see. Figure). | |||
Expansion module contains TVS, protect the relay contacts from arcing. Exterior protective components is not required. | |||
== | == Connecting to the 1-Wire network == | ||
Ground connect to GND or common ground bus. | |||
The data line to 1-Wire terminal. | |||
The supply line to 5Vout terminal (internal power supply). | |||
It is allowed to use external power supply bus 1-Wire. | |||
When using a passive power supply pin of each sensor is connected to the earth wire. | |||
In this case, the bus consists two wires attached, respectively, to '1-Wire "and" GND ". | |||
== | == Connecting to RS-485 network == | ||
See [[Special:MyLanguage/RS-485|RS-485]]. | |||
Wiren Board 5 has two RS-485 port. The second port is multiplexed with the port CAN (L with A, H with B) | |||
Line A B is connected to terminals A and B respectively. Signal ground (if any) connected to the ground controller. | |||
If the RS-485 network is long enough, then it is recommended to use [[Wiren Board 5: Модуль расширения RS485-ISO|extension module with galvanically-isolated RS-485]]. | |||
Строка 147: | Строка 147: | ||
=== | === Example of connection devices === | ||
Schematic test stand - [[Файл:Стенд-hi.jpg|thumb|500px|Schematic test stand]] |