Участник:EvgenyBoger/CT309-test/en: различия между версиями
FuzzyBot (обсуждение | вклад) (Обновление для соответствия новой версии исходной страницы.) |
(Новая страница: «An adapter with an RJ-12 socket is inserted into the WB-MAP meter instead of a mating terminal block and connected to the transformers with a connecting cable (included). The cable is made of a twisted pair and two 6P6C (RJ-12) plugs crimped in a straight pattern: white-orange, orange, white-green, green, white-blue, blue (see diagram 1).») |
||
(не показано 8 промежуточных версий 2 участников) | |||
Строка 1: | Строка 1: | ||
<languages/> | <languages/> | ||
{{DISPLAYTITLE: Сборка неразъемных трансформаторов WB-CT309}} | {{DISPLAYTITLE: Сборка неразъемных трансформаторов WB-CT309}} | ||
{{PDF}} | {{PDF}} | ||
Строка 11: | Строка 10: | ||
The assembly is intended for use in conjunction with WB-MAP meters as a replacement for split transformers. The use of one-piece transformers is often more convenient and reliable when assembling the shield from scratch. | The assembly is intended for use in conjunction with WB-MAP meters as a replacement for split transformers. The use of one-piece transformers is often more convenient and reliable when assembling the shield from scratch. | ||
<div lang="ru" dir="ltr" class="mw-content-ltr"> | <div lang="ru" dir="ltr" class="mw-content-ltr"> | ||
== Технические характеристики== | |||
</div> | </div> | ||
[[File:ErorrZMCT123.png|300px|thumb|right|Transformer current measurement error]] | [[File:ErorrZMCT123.png|300px|thumb|right|Transformer current measurement error]] | ||
Строка 38: | Строка 36: | ||
|Dimensions (L x W x H)|| 74 x 30 x 36 mm | |Dimensions (L x W x H)|| 74 x 30 x 36 mm | ||
|- | |- | ||
{{ | {{Wbincludes:Weight}} | ||
70 g | 70 g | ||
|} | |} | ||
Строка 53: | Строка 51: | ||
An adapter with an RJ-12 socket is inserted into the WB-MAP meter instead of a mating terminal block and connected to the transformers with a connecting cable (included). The cable is made of a twisted pair and two 6P6C (RJ-12) plugs crimped in a straight pattern: white-orange, orange, white-green, green, white-blue, blue (see diagram 1). | An adapter with an RJ-12 socket is inserted into the WB-MAP meter instead of a mating terminal block and connected to the transformers with a connecting cable (included). The cable is made of a twisted pair and two 6P6C (RJ-12) plugs crimped in a straight pattern: white-orange, orange, white-green, green, white-blue, blue (see diagram 1). | ||
<div lang="ru" dir="ltr" class="mw-content-ltr"> | |||
Если вы устанавливаете две трансформаторных сборки рядом и вторую переворачиваете, то один из концов кабеля нужно обжать по другой схеме: оранжевый, бело-оранжевый, зеленый, бело-зеленый, синий, бело-синий (см. схему 2). | |||
</div> | |||
<div lang="ru" dir="ltr" class="mw-content-ltr"> | |||
Не рекомендуется работа без подключения к счетчику WB-MAP. | |||
</div> | |||
<div lang="ru" dir="ltr" class="mw-content-ltr"> | |||
<gallery widths=260px heights=219px style="clear:both"> | <gallery widths=260px heights=219px style="clear:both"> | ||
Image: Installation WB-CT309.png | | Image: Installation WB-CT309.png | Выбор схемы обжима в зависимости от ориентации трансформаторной сборки | ||
Image: WBCT_RJ12_pinout.png | | Image: WBCT_RJ12_pinout.png | Схема 1. Обжим витой пары для подключения трансформаторной сборки. Серийный вариант | ||
Image: WBCT_RJ12_pinout invert.png | | Image: WBCT_RJ12_pinout invert.png | Схема 2. Обжим витой пары для подключения '''перевёрнутой''' трансформаторной сборки | ||
</gallery> | </gallery> | ||
</div> | |||
== | <div lang="ru" dir="ltr" class="mw-content-ltr"> | ||
== Известные неисправности == | |||
</div> | |||
<div lang="ru" dir="ltr" class="mw-content-ltr"> | |||
Известных неисправностей нет. | |||
</div> | |||
== | <div lang="ru" dir="ltr" class="mw-content-ltr"> | ||
== Ревизии устройства == | |||
</div> | |||
{{ | {{Wbincludes:Revision}} | ||
<div lang="ru" dir="ltr" class="mw-content-ltr"> | |||
|- | |- | ||
|1.4 | |1.4 | ||
Строка 77: | Строка 88: | ||
|06.2021 - ... | |06.2021 - ... | ||
| | | | ||
* | *Добавлены TVS на вторичной обмотке | ||
|- | |- | ||
|1.3 | |||
|v1.3A - v1.3E | |v1.3A - v1.3E | ||
|03.2021 - 11.2021 | |03.2021 - 11.2021 | ||
| | | | ||
* | *Первая ревизия | ||
|- | |- | ||
|} | |} | ||
</div> | |||
== | <div lang="ru" dir="ltr" class="mw-content-ltr"> | ||
== Изображения и чертежи устройства == | |||
</div> | |||
[[File:WBCT-309_drawing.png |350px|thumb|right| | <div lang="ru" dir="ltr" class="mw-content-ltr"> | ||
[[File:WBCT-309_drawing.png |350px|thumb|right|Габаритные размеры]] | |||
</div> | |||
{{Wbincludes:CDR lib}} | {{Wbincludes:CDR lib}} | ||
<div lang="ru" dir="ltr" class="mw-content-ltr"> | |||
'''Corel Draw PDF:''' [[File:CT3.cdr.pdf|File:CT3.cdr.pdf]] | '''Corel Draw PDF:''' [[File:CT3.cdr.pdf|File:CT3.cdr.pdf]] | ||
</div> |
Версия 16:47, 20 марта 2022
Purpose
The assembly is intended for use in conjunction with WB-MAP meters as a replacement for split transformers. The use of one-piece transformers is often more convenient and reliable when assembling the shield from scratch.
Технические характеристики
Parameter | Value |
---|---|
Rated current | 5 A |
Maximum current | 125 A |
Hole diameter (max. cable diameter) | 9.5 mm |
Transformation ratio | 1:2000 |
Phase angle, 1/1000 of a degree | 120 |
Dimensions (L x W x H) | 74 x 30 x 36 mm |
Масса (с коробкой) |
70 g |
Datasheet for used transformers: Файл:ZMCT123.pdf
Mounting
Step between transformers - 1 DIN module (17.5 mm). It is convenient to install the assembly immediately under the machines. They can also be joined two at a time by turning the right assembly over and crimping the second end of the cable in a different order - this way the step between the transformers will be preserved.! N! It can be attached to the shield panel using self-tapping screws to plastic racks. You can also simply fix it on the cable with ties (put it on the cable itself to limit the stroke).
An adapter with an RJ-12 socket is inserted into the WB-MAP meter instead of a mating terminal block and connected to the transformers with a connecting cable (included). The cable is made of a twisted pair and two 6P6C (RJ-12) plugs crimped in a straight pattern: white-orange, orange, white-green, green, white-blue, blue (see diagram 1).
Если вы устанавливаете две трансформаторных сборки рядом и вторую переворачиваете, то один из концов кабеля нужно обжать по другой схеме: оранжевый, бело-оранжевый, зеленый, бело-зеленый, синий, бело-синий (см. схему 2).
Не рекомендуется работа без подключения к счетчику WB-MAP.
Известные неисправности
Известных неисправностей нет.
Ревизии устройства
The batch number can be found on a sticker on the side of the case or on the PCB.
Revision | Batch | Release date | Differences from previous revision |
---|---|---|---|
1.4 | v1.4A, v1.4B - ... | 06.2021 - ... |
|
1.3 | v1.3A - v1.3E | 03.2021 - 11.2021 |
|
Изображения и чертежи устройства
Corel Draw 2018 (шрифт — Ubuntu): Файл:WB-Library.cdr.zip
Visio:
- Устройства Wiren Board: Файл:WB-Visio-Lib.cdr.zip.
- Щиты, автоматы, контакторы и прочее.
Corel Draw PDF: Файл:CT3.cdr.pdf