IO modules are joined to the connector on the side WB5. | |||
[[Файл:In-Out1.jpeg|300px|thumb|right| IO module]] | [[Файл:In-Out1.jpeg|300px|thumb|right| IO module]] | ||
[[Файл:In-out.png|300px|thumb|right|Pinout slot for input-output modules]] | |||
[[Файл: | |||
You can connect up to 8 modules: Up to 4 input modules (type I), and up to 4 output module (Type O and IO). | |||
WB5 automatically detects connected module and its type. | |||
Addresses are distributed sequentially. | |||
Connect up to 4 modules can be in any order. When a larger number should be connected first one type, then the other. | |||
Communication Interface - I2C. | |||
== Digital Input Module type "dry contact" (WBIO-DI-DR-8) == | |||
[[Файл:WBIO-DI-DR-8-small-crop.jpg|200px|thumb|none|WBIO-DI-DR-8 module]] | |||
Contains 8 inputs for connecting "dry contacts" with the group galvanic isolation. | |||
The circuit inputs shown in Fig. On input is applied ~ 4.5V, ground fault current flows small (1mA), triggering input. | |||
To input trigger pulse width must be at least 10 ms ???. The time between pulses - 5ms | |||
[[Файл:DI.png|300px|thumb|none|Digital inputs DI]] | |||
== Digital Output Module (WBIO-DO-HS-8) == | |||
[[Файл:WBIO-DO-HS-8-small-crop.jpg|200px|thumb|none|WBIO-DO-HS-8 module]] | |||
Contains 8 outputs such as "High Side Switch" - when you turn on channel Vin voltage is supplied to the output. | |||
Designed to control relays, low-voltage motors, etc. | |||
Current up to 0,6A per channel. Built-in overvoltage protection (including load dump), overheat and short circuit protection. | |||
Requires external power supply to the terminals '' 'Vin' '' and '' 'GND' ''. | |||
Ground module must be connected with the ground controller! | |||
Power supply from 11 to 45V. | |||
[[Файл:HSx.png|300px|thumb|none|The circuit of High Side Outputs module.]] | |||
== Relay Output Module (WBIO-DO-R3A-8) == | |||
[[Файл:WBIO-DO-R3A-8-small-crop.jpg|200px|thumb|none|WBIO-DO-HS-8 module]] | |||
| | |||
| | |||
| | |||
|WBIO- | |||
Contains 8 relays. Two of them are SPDT (NO / COM / NC). | |||
Current up to 10A per channel NO-NC (on / off), up to 3A channels SPDT relay. Protection from arcing contacts. | |||
Rated current is specified for resistive loads and 230V AC. | |||
== IO module with TTL-level (WBIO-DIO-TTL-8) == | |||
[[Файл:WBIO-DIO-TTL-8-small-crop.jpg|200px|thumb|none|WBIO-DIO-TTL-8 module]] | |||
[[Файл: | It contains 8 GPIO channels with 5V level, the channels are configured by default as a "outputs." | ||
Up to 20 mA. Overvoltage protection up to 60V. | |||
== Мезонинный модуль ввода-вывода с TTL-уровнями (WBMZ-DIO-TTL-16) == | |||
Основная статья: [[Special:MyLanguage/WBMZ-DIO-TTL-16|WBMZ-DIO-TTL-16]]. |
Версия 18:51, 14 января 2016
IO modules are joined to the connector on the side WB5.
You can connect up to 8 modules: Up to 4 input modules (type I), and up to 4 output module (Type O and IO). WB5 automatically detects connected module and its type. Addresses are distributed sequentially. Connect up to 4 modules can be in any order. When a larger number should be connected first one type, then the other.
Communication Interface - I2C.
Digital Input Module type "dry contact" (WBIO-DI-DR-8)
Contains 8 inputs for connecting "dry contacts" with the group galvanic isolation. The circuit inputs shown in Fig. On input is applied ~ 4.5V, ground fault current flows small (1mA), triggering input.
To input trigger pulse width must be at least 10 ms ???. The time between pulses - 5ms
Digital Output Module (WBIO-DO-HS-8)
Contains 8 outputs such as "High Side Switch" - when you turn on channel Vin voltage is supplied to the output.
Designed to control relays, low-voltage motors, etc.
Current up to 0,6A per channel. Built-in overvoltage protection (including load dump), overheat and short circuit protection.
Requires external power supply to the terminals 'Vin' and 'GND' .
Ground module must be connected with the ground controller!
Power supply from 11 to 45V.
Relay Output Module (WBIO-DO-R3A-8)
Contains 8 relays. Two of them are SPDT (NO / COM / NC).
Current up to 10A per channel NO-NC (on / off), up to 3A channels SPDT relay. Protection from arcing contacts.
Rated current is specified for resistive loads and 230V AC.
IO module with TTL-level (WBIO-DIO-TTL-8)
It contains 8 GPIO channels with 5V level, the channels are configured by default as a "outputs." Up to 20 mA. Overvoltage protection up to 60V.
Мезонинный модуль ввода-вывода с TTL-уровнями (WBMZ-DIO-TTL-16)
Основная статья: WBMZ-DIO-TTL-16.