Matveevrj (обсуждение | вклад) (Новая страница: «{| class="wikitable" style="margin:auto; text-align:center" |- ! scope="col" style="width:20%" | ! scope="col" style="width:20%" | WB-UPS ! scope="col" style="width:20%" | WBMZ-BATTERY ! scope="col" style="width:20%" | WBMZ-SUPERCAP ! scope="col" style="width:20%" | MeanWell DRC-40 |- ! scope="row"; style="text-align:left" | Rated power | 15 W|| 6 W || 7 W || 40 W |- ! scope="row"; style="text-align:left" | Operating time at rated power | 50 minutes || 4 ho...») |
Matveevrj (обсуждение | вклад) |
||
(не показана 1 промежуточная версия этого же участника) | |||
Строка 1: | Строка 1: | ||
<languages/>{{DISPLAYTITLE: Backup power for Wiren Board devices}} | <languages/>{{DISPLAYTITLE: Backup power for Wiren Board devices}} | ||
An external backup power module can be used to provide backup power for the controller and peripheral devices of the Wiren Board | An external backup power module can be used to provide backup power for the controller and peripheral devices of the Wiren Board sach as [[WB-UPS2 Backup power supply for DIN rails | WB-UPS v.2]], plug-in modules [[WBMZ4-BATTERY Backup Power Module | WBMZ-BATTERY]] and [[WBMZ4-SUPERCAP Backup Power Module | WBMZ-SUPERCAP]], or UPS other manufacturer, for example, [https://www.meanwell.com/Upload/PDF/DRC-40/DRC-40-SPEC.PDF MEAN WELL DRC-40]. | ||
<gallery mode="packed" heights="200 px"> | <gallery mode="packed" heights="200 px"> | ||
Строка 9: | Строка 9: | ||
</gallery> | </gallery> | ||
==Specifications of the | ==Specifications of the UPS's== | ||
{| class="wikitable" style="margin:auto; text-align:center" | {| class="wikitable" style="margin:auto; text-align:center" |
Текущая версия на 21:54, 13 сентября 2022
An external backup power module can be used to provide backup power for the controller and peripheral devices of the Wiren Board sach as WB-UPS v.2, plug-in modules WBMZ-BATTERY and WBMZ-SUPERCAP, or UPS other manufacturer, for example, MEAN WELL DRC-40.
Specifications of the UPS's
WB-UPS | WBMZ-BATTERY | WBMZ-SUPERCAP | MeanWell DRC-40 | |
---|---|---|---|---|
Rated power | 15 W | 6 W | 7 W | 40 W |
Operating time at rated power | 50 minutes | 4 hours | 45 seconds | Depends on the capacity of the battery used |
Occupied space on the DIN rail | 2 units | Does not take | Does not take |
2 units and a place for a lead battery |
Operating temperature | 0 °C to 45 °C | 0 °C to 50 °C | −40 °C to 85 °C | −40 °C to 85 °C |
Charge time | 4 hours | 4 hours | 5 minutes | - |
Number of charge-discharge cycles | 500...1000 | 500...1000 | over 500 000 | - |
«Status» signal | «open collector» | in the web interface of the controller | in the web interface of the controller | «open collector» |
Use without Wiren Board controller | Yes | No | No | Yes |
Application | Maintaining operability when switching from the main source of power supply to the backup | Maintaining performance during short-term power outages | Autonomous operation during long-term power outages |