I/O Mapping Matrix/en: различия между версиями
(Новая страница: «Thus, it is possible to program the response of each output to the closure and disconnection of any inputs. <!-- {| class="wikitable" ! !! !! ! colspan="4" |R…») |
(Новая страница: «--> {| class="wikitable" ! !! !! ! colspan="4" |back |- ! | || style="text-align:center;"| '''00''' || style="text-align:center;"| '''01''' || style="text-al…») |
||
Строка 55: | Строка 55: | ||
--> | --> | ||
{| class="wikitable" | {| class="wikitable" | ||
! !! !! ! colspan="4" | | ! !! !! ! colspan="4" |back | ||
|- | |- | ||
! | ! | ||
| || style="text-align:center;"| '''00''' || style="text-align:center;"| '''01''' || style="text-align:center;"| '''10''' || style="text-align:center;"| '''11''' | | || style="text-align:center;"| '''00''' || style="text-align:center;"| '''01''' || style="text-align:center;"| '''10''' || style="text-align:center;"| '''11''' | ||
|- style="vertical-align:center;" | |- style="vertical-align:center;" | ||
! rowspan="4"| | ! rowspan="4"|front<br> | ||
| '''00''' | | '''00''' | ||
| style="text-align:center;vertical-align:bottom;" | [[File:Mm_0000.png|frameless|270px]]<br>(0) — | | style="text-align:center;vertical-align:bottom;" | [[File:Mm_0000.png|frameless|270px]]<br>(0) — Input is disabled, does not control outputs | ||
| style="text-align:center;vertical-align:bottom;" | [[File:Mm_0001.png|frameless|270px]]<br>(1) — | | style="text-align:center;vertical-align:bottom;" | [[File:Mm_0001.png|frameless|270px]]<br>(1) — Disable when opening circuit | ||
| style="text-align:center;vertical-align:bottom;" | [[File:Mm_0010.png|frameless|270px]]<br>(2) — | | style="text-align:center;vertical-align:bottom;" | [[File:Mm_0010.png|frameless|270px]]<br>(2) — Enable when circuit is open | ||
| style="text-align:center;vertical-align:bottom;" | [[File:Mm_0011.png|frameless|270px]]<br>(3) — | | style="text-align:center;vertical-align:bottom;" | [[File:Mm_0011.png|frameless|270px]]<br>(3) — Change the exit status when closing | ||
|- style="vertical-align:center;" | |- style="vertical-align:center;" | ||
| '''01''' | | '''01''' | ||
| style="text-align:center;vertical-align:bottom;" | [[File:Mm_0100.png|frameless|270px]]<br>(4) — | | style="text-align:center;vertical-align:bottom;" | [[File:Mm_0100.png|frameless|270px]]<br>(4) — Turn off when snapping | ||
| style="text-align:center;vertical-align:bottom;" | [[File:Mm_0101.png|frameless|270px]]<br>(5) — ''' | | style="text-align:center;vertical-align:bottom;" | [[File:Mm_0101.png|frameless|270px]]<br>(5) — '''Always turn off''' | ||
| style="text-align:center;vertical-align:bottom;" | [[File:Mm_0110.png|frameless|270px]]<br>(6) | | style="text-align:center;vertical-align:bottom;" | [[File:Mm_0110.png|frameless|270px]]<br>(6) —Work as an inverted <br>safety switch with separate actuator | ||
| style="text-align:center;vertical-align:bottom;" | [[File:Mm_0111.png|frameless|270px]]<br>(7) — | | style="text-align:center;vertical-align:bottom;" | [[File:Mm_0111.png|frameless|270px]]<br>(7) — Turn off when opening, then <br>change state when switching | ||
|- style="vertical-align:center;" | |- style="vertical-align:center;" | ||
| '''10''' | | '''10''' | ||
| style="text-align:center;vertical-align:bottom;" | [[File:Mm_1000.png|frameless|270px]]<br>(8) — | | style="text-align:center;vertical-align:bottom;" | [[File:Mm_1000.png|frameless|270px]]<br>(8) — Turn on when the circuit is closed | ||
| style="text-align:center;vertical-align:bottom;" | [[File:Mm_1001.png|frameless|270px]]<br>(9) — | | style="text-align:center;vertical-align:bottom;" | [[File:Mm_1001.png|frameless|270px]]<br>(9) — To work like '''locking swich''' <br>(repeat sign) | ||
| style="text-align:center;vertical-align:bottom;" | [[File:Mm_1010.png|frameless|270px]]<br>(10, 0x0A)— | | style="text-align:center;vertical-align:bottom;" | [[File:Mm_1010.png|frameless|270px]]<br>(10, 0x0A)— Always turn on | ||
| style="text-align:center;vertical-align:bottom;" | [[File:Mm_1011.png|frameless|270px]]<br>(11, 0x0B) — | | style="text-align:center;vertical-align:bottom;" | [[File:Mm_1011.png|frameless|270px]]<br>(11, 0x0B) — Enable, then change the <br>state when opening | ||
|- style="vertical-align:center;" | |- style="vertical-align:center;" | ||
| '''11''' | | '''11''' | ||
| style="text-align:center;vertical-align:bottom;" | [[File:Mm_1100.png|frameless|270px]]<br>(12, 0x0C) — | | style="text-align:center;vertical-align:bottom;" | [[File:Mm_1100.png|frameless|270px]]<br>(12, 0x0C) — To change the output state <br>in short<br>("'non-latching switch"') | ||
| style="text-align:center;vertical-align:bottom;" | [[File:Mm_1101.png|frameless|270px]]<br>(13, 0x0D) — | | style="text-align:center;vertical-align:bottom;" | [[File:Mm_1101.png|frameless|270px]]<br>(13, 0x0D) — Change state, then <br>turn off when opening | ||
| style="text-align:center;vertical-align:bottom;" | [[File:Mm_1110.png|frameless|270px]]<br>(14, 0x0E) — | | style="text-align:center;vertical-align:bottom;" | [[File:Mm_1110.png|frameless|270px]]<br>(14, 0x0E) — Change state, then <br>turn off when circuit is open | ||
| style="text-align:center;vertical-align:bottom;" | [[File:Mm_1111.png|frameless|270px]]<br>(15, 0x0F) — | | style="text-align:center;vertical-align:bottom;" | [[File:Mm_1111.png|frameless|270px]]<br>(15, 0x0F) — Change the state when closing<br>and return to the original state<br>when opening | ||
|} | |} | ||