Периферийные устройства с интерфейсом RS-485 серии WB-xxxx/en: различия между версиями
(Новая страница: «=== Discontinued modules ===») |
Matveevrj (обсуждение | вклад) |
||
(не показано 5 промежуточных версий 1 участника) | |||
Строка 84: | Строка 84: | ||
|} | |} | ||
=== Discontinued | === Discontinued models === | ||
{| class="wikitable" | {| class="wikitable" | ||
|[[Универсальный датчик WB-MS|WB-MSW - | |[[Универсальный датчик WB-MS|WB-MSW v.1, v.2 hybrid sensors in wall-mounted enclosure]] | ||
| | | | ||
|- | |- | ||
|[[WB-MIR v1 - Modbus IR Remote Control| | |[[WB-MIR v1 - Modbus IR Remote Control|Modbus IR Remote Control WB-MIR v1]] | ||
|[[Файл:WB-MIR-sample.png|100px]] | |[[Файл:WB-MIR-sample.png|100px]] | ||
|- | |- | ||
|[[WB-MR11_Modbus_Relay_11_Channel_Module| | |[[WB-MR11_Modbus_Relay_11_Channel_Module| 11 Channel Modbus Relay Module WB-MR11]] | ||
|[[File:WB-MR11.jpg|100px]] | |[[File:WB-MR11.jpg|100px]] | ||
|- | |- | ||
|[[WB-MR14 Modbus 14 Channel Relay Module| | |[[WB-MR14 Modbus 14 Channel Relay Module| 14 Channel Relay Module WB-MR14]] | ||
|[[Файл:MR14-2.jpg|100px]] | |[[Файл:MR14-2.jpg|100px]] | ||
|- | |- | ||
|[[WB-MRM2 Реле 2х канальное | | |[[WB-MRM2 Реле 2х канальное | 2-channel relay module MRM2]] | ||
|[[Файл:Relay.jpg |100px]] | |[[Файл:Relay.jpg |100px]] | ||
|- | |- | ||
|[[WB-MAO4 Modbus Dimmer|WB-MAO4 | |[[WB-MAO4 Modbus Dimmer| 4-channel dimmer WB-MAO4 (0-10В, PWM)]] | ||
|- | |- | ||
|[[WB-MCM16 Модуль счетных входов 16-канальный | |[[WB-MCM16 Модуль счетных входов 16-канальный|Модуль счетных входов 16-канальный WB-MCM16 (нажимные клемники)]] | ||
|[[File:WB-MCM16 tilt.jpg |100px]] | |[[File:WB-MCM16 tilt.jpg |100px]] | ||
|- | |- | ||
|[[WB-MRGB| WB-MRGB | |[[WB-MRGB| WB-MRGB LED dimmer]] | ||
|[[Файл:WB-MRGB.png |100px]] | |[[Файл:WB-MRGB.png |100px]] | ||
|- | |- | ||
|[[WB-MRGB-D| WB-MRGB-D - | |[[WB-MRGB-D| WB-MRGB-D - Din-railed LED dimmer]] | ||
|[[Файл:MRGB-D.png |100px]] | |[[Файл:MRGB-D.png |100px]] | ||
|- | |- | ||
|[[WB-MD2_230V_Dimmer| | |[[WB-MD2_230V_Dimmer| | ||
LED and incandescent lamps dimmer WB-MD2]] | |||
|[[File:WB_MD2_small.png |100px]] | |[[File:WB_MD2_small.png |100px]] | ||
|- | |- | ||
|} | |} | ||
== | == How to install a new Modbus address on our RS-485 device== | ||
# | # Connect the device to the controller, ONLY this device should be connected via the BUS. | ||
#: | #: '''If you connect several devices on the bus, their performance will be disrupted!''' | ||
# | # Run the [[SSH | console]] commands: | ||
<syntaxhighlight lang="bash"> | <syntaxhighlight lang="bash"> | ||
service wb-mqtt-serial stop # | service wb-mqtt-serial stop # stop the standard RS-485 driver | ||
# | # In the next line, replace "158" with the new address (1 to 247) and "/dev/ttyAPP1" with the controller port to which the device is connected | ||
modbus_client --debug -m rtu -s2 -pnone /dev/ttyAPP1 -a0x00 -t0x06 -r0x80 158 # | modbus_client --debug -m rtu -s2 -pnone /dev/ttyAPP1 -a0x00 -t0x06 -r0x80 158 # write new address to device | ||
service wb-mqtt-serial start # | service wb-mqtt-serial start # start the standard RS-485 driver again | ||
</syntaxhighlight> | </syntaxhighlight> | ||
== | == Device firmware update == | ||
Starting with the new firmware versions of the device, the firmware update functionality (firmware) via the Modbus Protocol is supported. This makes it possible to extend the functionality of the devices and eliminate errors in the firmware directly at the installation site. Read more about flashing devices described in the article [[WB-MCU-Flasher|Download firmware to Wiren Board devices]]. A list of firmware versions that support the update, as well as devices for which this feature is implemented, can be found in [[Firmware_Changelog]]. |
Текущая версия на 15:22, 21 февраля 2023
We produce our own peripherals connected via RS-485 (Modbus).
They are guaranteed to be compatible with the Wiren Board controller and have the best software support.
Current models
Current models for special solutions
WB-MR6F Modbus relay module for stepped control of two fans | |
Modbus Analog inputs module WB-MAI |
Discontinued models
How to install a new Modbus address on our RS-485 device
- Connect the device to the controller, ONLY this device should be connected via the BUS.
- If you connect several devices on the bus, their performance will be disrupted!
- Run the console commands:
service wb-mqtt-serial stop # stop the standard RS-485 driver
# In the next line, replace "158" with the new address (1 to 247) and "/dev/ttyAPP1" with the controller port to which the device is connected
modbus_client --debug -m rtu -s2 -pnone /dev/ttyAPP1 -a0x00 -t0x06 -r0x80 158 # write new address to device
service wb-mqtt-serial start # start the standard RS-485 driver again
Device firmware update
Starting with the new firmware versions of the device, the firmware update functionality (firmware) via the Modbus Protocol is supported. This makes it possible to extend the functionality of the devices and eliminate errors in the firmware directly at the installation site. Read more about flashing devices described in the article Download firmware to Wiren Board devices. A list of firmware versions that support the update, as well as devices for which this feature is implemented, can be found in Firmware_Changelog.