WB-MS | 3.10.1 | WB-MS, WB-M1W2, WB-MIR | 1-wire reset time changed from ~410 us to ~550 us. As in 1-Wire Standard, should be between 480 and 640 us
|
|
|
|-
|-
|
WB-MS | 3.10.0 | WB-MS, WB-M1W2, WB-MIR | added filter out algorithm for suspicious values 85C and 127.937C from 1-wire temperature sensors
|
 
|
}
|
|}

Версия 10:51, 22 марта 2018

Общая таблица по всем устройствам

WB-MS | 3.10.1 | WB-MS, WB-M1W2, WB-MIR | 1-wire reset time changed from ~410 us to ~550 us. As in 1-Wire Standard, should be between 480 and 640 us WB-MS | 3.10.0 | WB-MS, WB-M1W2, WB-MIR | added filter out algorithm for suspicious values 85C and 127.937C from 1-wire temperature sensors }