wb_editors
14 355
правок
(Новая страница: «300px|thumb|right|overall dimensions {| class="wikitable" ! style="text-align: center;" | Option ! style="text-align: center;" | Value |- ! c…») |
FuzzyBot (обсуждение | вклад) (Часть переводимой страницы WB-MIO.) |
||
(не показаны 22 промежуточные версии 2 участников) | |||
Строка 101: | Строка 101: | ||
|- | |- | ||
! colspan="2" | | ! colspan="2" |dimensions | ||
|- | |- | ||
| | | Size | ||
| 2 DIN; 36,3x90,2x57,5 | | 2 DIN; 36,3x90,2x57,5 mm | ||
|- | |- | ||
! colspan="2" | | ! colspan="2" |Operating conditions | ||
|- | |- | ||
| | | Air temperature | ||
| | | -40°C to +80°C | ||
|- | |- | ||
| | | Relative humidity | ||
| | | up to 92%, no condensation | ||
|} | |} | ||
== | == Modifications== | ||
Interface module WB-MIO is available in two versions, characterized by the presence of Ethernet interface: WB-MIO and WB-MIO-E. | |||
{| class="wikitable" | {| class="wikitable" | ||
! | !Modification | ||
! | !RS-485 interface | ||
! | !Ethernet interface | ||
|- | |- | ||
|WB-MIO | |WB-MIO | ||
|''' | |'''yes''' | ||
| | |no | ||
|- | |- | ||
|WB-MIO-E | |WB-MIO-E | ||
|''' | |'''yes''' | ||
|''' | |'''yes''' | ||
|} | |} | ||
== | ==RS-485 interface connection== | ||
[[ | [[File:Installation WB6+mio.png|300px|thumb| WB-MIO RS-485 Connection]] | ||
'''WB-MIO(-E)''' | '''WB-MIO(-E)''' is connected to the controller via connectors A and B RS-485. If power is supplied from a separate power supply, the ground of the controller and the power supply must be combined. | ||
See article[[RS-485:Физическое подключение/en| RS-485:Physical connection]]. | |||
The WB-MIO module is a peripheral device (slave) in the Modbus network. | |||
== | == Ethernet connection == | ||
Modification '''WB-MIO-E''' with Ethernet interface is connected to the local Ethernet network: to the router port or directly to one of the Ethernet ports of the programmable Wiren Board controller. | |||
'''WB-MIO-E''' power is supplied to V+ and GND terminals. Module WB-MIO-E '''does NOT''' support PoE. | |||
On the default Ethernet network, ''WB-MIO-E''' has a static IP address of 192.168.0.7. To work with the Wiren Board controller software, the Ethernet part of the WB-MIO-E module must be configured in "TCP Server" mode. Detailed instructions on how to configure the Ethernet part of WB-MIO-E can be found on [[WB-MIO-E_AND_WB-MGE_Ethernet_Connection_Setup/en|configuring Ethenet interfaces and connecting WB-MIO-E and WB-MGE modules]]]. | |||
== | ==Connection of I/O modules== | ||
I/O modules are connected to the WB-MIO by connecting to it from the side (entering the side connector). | |||
[[ | [[File:Connecting_Side_Modules.png|250px|thumb|right| Connecting the module to WB-MIO]] | ||
Up to 9 modules can be connected in series: up to 4 input modules (type "I"), up to 4 output and I / o modules (type "O" and "IO"), one WBIO-AI-DV-12 module. The module type determines the type of module addressing by the controller on the side connector bus. Addresses are distributed in sequence. Up to 4 modules can be connected in any sequence. With a larger number, you should connect one type first, then another. | |||
== | ==Configuration in the web interface== | ||
[[Драйвер wb-mqtt-serial/en|Wb-mqtt-serial driver] is responsible for working with WB-MIO(-E) connected via RS-485 or Ethernet in the Wiren Board controllers. | |||
To connect [[Модули ввода-вывода/en|'''WBIO''' modules]] via WB-MIO, go to the web interface of the controller, to the Configs tab, select the /etc/wb-mqtt-serial file.conf. Next, you need to add a new Serial device to the required port. In the field "Slave id of the device" specify the address of the WB-MIO device, add a colon, then number on the count of connected I/o module in a row. | |||
For example, if we have only one module connected to WB-MIO, the string "Slave id of the device" for this module will look like this: 15:1. Where 15 is the Modbus address of WB-MIO and 1 is the I/O module account number. In the "Device type" field, select the type of the connected module. Template names for them start with "WBIO-..." | |||
[[Файл:Mio-conf2.JPG|Файл:Mio-conf2.JPG]] [[Файл:Mio-conf3.JPG|Файл:Mio-conf3.JPG]] [[Файл:Mio-conf1.png|Файл:Mio-conf1.png]] | [[Файл:Mio-conf2.JPG|Файл:Mio-conf2.JPG]] [[Файл:Mio-conf3.JPG|Файл:Mio-conf3.JPG]] [[Файл:Mio-conf1.png|Файл:Mio-conf1.png]] | ||
== | ==Modbus Control== | ||
A map of the WB-MIO and WB-MIO-E Modbus registers can be found on [[WB-MIO-Modbus-Registers/en]]. For more information on working with Modbus devices, see [[Протокол Modbus/en|Modbus Protocol]] | |||
== | == Images and drawings of the device == | ||
{{Wbincludes:WBPicturesNoDrawing|1}} | {{Wbincludes:WBPicturesNoDrawing|1}} | ||
<!--{{Wbincludes:WBPictures|1}}--> | <!--{{Wbincludes:WBPictures|1}}--> | ||
{{Wbincludes:WBPictures|2}} | {{Wbincludes:WBPictures|2}} |