'''WB-MIO-E''' power is supplied to V+ and GND terminals. Module WB-MIO-E '''does NOT''' support PoE. | '''WB-MIO-E''' power is supplied to V+ and GND terminals. Module WB-MIO-E '''does NOT''' support PoE. | ||
On the default Ethernet network, ''WB-MIO-E''' has a static IP address of 192.168.0.7. To work with the Wiren Board controller software, the Ethernet part of the WB-MIO-E module must be configured in "TCP Server" mode. Detailed instructions on how to configure the Ethernet part of WB-MIO-E can be found on [[WB-MIO-E_AND_WB-MGE_Ethernet_Connection_Setup/en|configuring Ethenet interfaces and connecting WB-MIO-E and WB-MGE modules]]]. | On the default Ethernet network, ''WB-MIO-E''' has a static IP address of 192.168.0.7. To work with the Wiren Board controller software, the Ethernet part of the WB-MIO-E module must be configured in "TCP Server" mode. Detailed instructions on how to configure the Ethernet part of WB-MIO-E can be found on [[WB-MIO-E_AND_WB-MGE_Ethernet_Connection_Setup/en|configuring Ethenet interfaces and connecting WB-MIO-E and WB-MGE modules]]]. | ||
==Connection of I/O modules== | ==Connection of I/O modules== | ||
Строка 164: | Строка 162: | ||
==Configuration in the web interface== | ==Configuration in the web interface== | ||
[[Драйвер wb-mqtt-serial/en|Wb-mqtt-serial driver] is responsible for working with WB-MIO(-E) connected via RS-485 or Ethernet in the Wiren Board controllers. | [[Драйвер wb-mqtt-serial/en|Wb-mqtt-serial driver] is responsible for working with WB-MIO(-E) connected via RS-485 or Ethernet in the Wiren Board controllers. | ||
To connect [[Модули ввода-вывода/en|'''WBIO''' modules]] via WB-MIO, go to the web interface of the controller, to the Configs tab, select the /etc/wb-mqtt-serial file.conf. Next, you need to add a new Serial device to the required port. In the field "Slave id of the device" specify the address of the WB-MIO device, add a colon, then number on the count of connected I/o module in a row. | To connect [[Модули ввода-вывода/en|'''WBIO''' modules]] via WB-MIO, go to the web interface of the controller, to the Configs tab, select the /etc/wb-mqtt-serial file.conf. Next, you need to add a new Serial device to the required port. In the field "Slave id of the device" specify the address of the WB-MIO device, add a colon, then number on the count of connected I/o module in a row. |