WB-MR6F Modbus Relay Module/en: различия между версиями

Новая страница: «The Safety Timer slider allows you to set the shutdown time (in seconds) of all outputs when there is no communication with the Wiren Board (0 – the safety time…»
(Новая страница: «Using virtual switches K1-K6 in the web-interface, you can control the corresponding outputs of the module and monitor their status. If the relay is turned on or…»)
(Новая страница: «The Safety Timer slider allows you to set the shutdown time (in seconds) of all outputs when there is no communication with the Wiren Board (0 – the safety time…»)
Строка 234: Строка 234:
The current state of the inputs is indicated by the Input1 — Input6 checkboxes (they cannot be clicked to change the state). Press/enable counters are displayed in the Input 1 counter – Input 6 counter fields. The meter values are stored in the memory of the relay module microcontroller and are reset when the power is turned on/off and reset.
The current state of the inputs is indicated by the Input1 — Input6 checkboxes (they cannot be clicked to change the state). Press/enable counters are displayed in the Input 1 counter – Input 6 counter fields. The meter values are stored in the memory of the relay module microcontroller and are reset when the power is turned on/off and reset.


Ползунок Safety Timer позволяет задать время отключения (в секундах) всех выходов при отсутствии обмена данными с Wiren Board (0 – таймер безопасности отключен). При возобновлении связи с контроллером выключившиеся реле останутся выключенными. Ползунком удобно управлять с помощью клавиш со стрелками, предварительно сфокусировавшись на нем мышью: перемещение ползунка с помощью мыши не обеспечивает достаточную точность. Таймер безопасности позволяет остановить технологические процессы в случае, если контроль над модулем утрачен (например, перебит кабель RS-485).
The Safety Timer slider allows you to set the shutdown time (in seconds) of all outputs when there is no communication with the Wiren Board (0 – the safety timer is disabled). When communication with the controller is resumed, the switched-off relays will remain switched off. The slider is easy to control with the arrow keys, previously focusing on it with the mouse: moving the slider with the mouse does not provide sufficient accuracy. The safety timer allows stopping technological processes in case the control over the module is lost (for example, the RS-485 cable is broken).


Кнопка, подключенная ко входу 0, позволяет отключить все включенные реле модуля одним нажатием. Повторное нажатие включит все реле, которые были включены изначально. Состояние реле хранится в оперативной памяти, поэтому если повторной нажатие кнопки произойдет после перебоя питания, восстановления состояния реле не произойдет. Возможность восстановления состояния реле после перебоя питания описана в разделе [[#Режим работы реле в случае отключении питания|Режим работы реле в случае отключении питания]].
Кнопка, подключенная ко входу 0, позволяет отключить все включенные реле модуля одним нажатием. Повторное нажатие включит все реле, которые были включены изначально. Состояние реле хранится в оперативной памяти, поэтому если повторной нажатие кнопки произойдет после перебоя питания, восстановления состояния реле не произойдет. Возможность восстановления состояния реле после перебоя питания описана в разделе [[#Режим работы реле в случае отключении питания|Режим работы реле в случае отключении питания]].
12 063

правки