WBIO-AI-DCM-4 I/O Module/en: различия между версиями

Материал из Wiren Board
(Новая страница: «Contains 4 inputs for Hall sensors for load current measurement and 1 (2) input for voltage measurement.»)
(Новая страница: «{| class="wikitable" !Parameter !Value |- ! colspan="2" |voltage measuring Inputs |- | rowspan="2" |Number of inputs |2 (single-ended) |- |1 (differential) |- |In…»)
Строка 14: Строка 14:


{| class="wikitable"
{| class="wikitable"
!Параметр
!Parameter
!Значение
!Value
|-
|-
! colspan="2" |Входы для измерения напряжения
! colspan="2" |voltage measuring Inputs
|-
|-
| rowspan="2" |Количество входов
| rowspan="2" |Number of inputs
|2 (single-ended)
|2 (single-ended)
|-
|-
|1 (дифференциальный)
|1 (differential)
|-
|-
|Тип входов
|Input type
|измерение напряжения,
|voltage measurement,
неизолированные
uninsulated
|-
|-
|Измеряемое напряжение
|Measured voltage
|48V DC (0-70V)
|48V DC (0-70V)
|-
|-
|Допустимое напряжение
|Allowable voltage
| -70V ... +70V DC
| -70V ... +70V DC
|-
|-
|Входное сопротивление
|Input impedance
|10 kOhm
|10 kOhm
|-
|-
! colspan="2" |Входы для измерения тока
! colspan="2" |current measuring Inputs
|-
|-
|Количество входов
|Number of inputs
|4
|4
|-
|-
|Тип входов
|Input type
|подключение датчиков Холла
|connecting hall sensors
|-
|-
|Тип датчиков
|Sensor type
|open-loop,  
|open-loop,  
питание 5V,  
5V power supply,  


выход 2.5V +/- 0.625V (FS)
выход 2.5V +/- 0.625V (FS)

Версия 20:01, 19 июля 2019

Другие языки:

Module is discontinued and replaced by WBIO-AI-DV-12 module

Purpose

The device is designed for tasks that require monitoring of currents and voltages in DC networks, for example for technical metering of electricity.

The device directly measures the voltage and current in the load. The values obtained are used to calculate power (kW) and energy (kWh).

Technical specifications

Contains 4 inputs for Hall sensors for load current measurement and 1 (2) input for voltage measurement.

Parameter Value
voltage measuring Inputs
Number of inputs 2 (single-ended)
1 (differential)
Input type voltage measurement,

uninsulated

Measured voltage 48V DC (0-70V)
Allowable voltage -70V ... +70V DC
Input impedance 10 kOhm
current measuring Inputs
Number of inputs 4
Input type connecting hall sensors
Sensor type open-loop,

5V power supply,

выход 2.5V +/- 0.625V (FS)

Допустимое напряжение -5V .. +5V
Выход питания для датчиков Холла 5V, общий для всех датчиков

с защитой от КЗ

Прочее
Тип модуля "I" (inverted address scheme)
Максимальная потребляемая мощность 0,1 Вт
Ширина, DIN юнитов 2
Размер 36,3x90,2x57,5 мм
Габаритные размеры

Подключение к контроллеру

Смотрите раздел Активирование нового модуля в веб-интерфейсе контроллера


Подключение

WBIO-AI-DCM-4 Wiring