Перейти к содержанию

Навигация

WBIO-AI-DV-12 Analog Inputs/en: различия между версиями

Часть переводимой страницы WBIO-AI-DV-12 I/O Module.
(Новая страница: «{| class="wikitable" style="text-align:center" |+ Dependence of the input operation mode on the installed jumper and scaling factor !"'The presence of the jumper"…»)
(Часть переводимой страницы WBIO-AI-DV-12 I/O Module.)
 
(не показано 12 промежуточных версий 2 участников)
Строка 1: Строка 1:
<languages/>
<languages/>
{{#vardefine:ProductFullName1|analog WBIO-AI-DV-12}} {{#vardefine:FileName1|WBIO-AI-DV-12}} {{#vardefine:ProductName1|WBIO-AI-DV-12}} {{#vardefine:ProductFullName2|analog WBIO-AI-DV-12 to measure analog signals 4-20mA}} {{#vardefine:FileName2|WBIO-AI-DV-12_4-20}} {{#vardefine:ProductName2|WBIO-AI-DV-12_4-20}}  
{{#vardefine:ProductFullName1|analog WBIO-AI-DV-12 module}} {{#vardefine:FileName1|WBIO-AI-DV-12}} {{#vardefine:ProductName1|WBIO-AI-DV-12}} {{#vardefine:ProductFullName2|analog WBIO-AI-DV-12 module for measuring 4-20mA analog signals}} {{#vardefine:FileName2|WBIO-AI-DV-12_4-20}} {{#vardefine:ProductName2|WBIO-AI-DV-12_4-20}}  
[[File:WBIO-AI-DV-12.png|mini|WBIO-AI-DV-12 ]]
[[File:WBIO-AI-DV-12.png|мини|WBIO-AI-DV-12]]


The module is designed for industrial and home automation systems and is used to measure the values of analog signals. Typical applications of the module can be considered as receiving data with analog thermometers or measurement of the stresses for each element batteries.
The module is designed for industrial and home automation systems and is used to measure the values of analog signals. Typical applications of the module can be considered as receiving data with analog thermometers or measurement of the stresses for each element batteries.
Строка 8: Строка 8:




'''[https://wirenboard.com/en/product/WBIO-AI-DV-12/ Buy WBIO-AI-DV-12 in the online store ]'''
'''[https://wirenboard.com/en/product/WBIO-AI-DV-12/ Buy WBIO-AI-DV-12]'''
'''[https://wirenboard.com/en/product/WBIO-AI-DV-12_4-20MA/ Buy WBIO-AI-DV-12_4-20MA in the online store]'''  
 
'''[https://wirenboard.com/ru/product/WBIO-AI-DV-12_4-20MA/ Buy WBIO-AI-DV-12 4-20MA]'''  


For a description of the current input module WBIO-AI-DV-12_4-20 mA, see [[WBIO-AI-DV-12 4-20MA/en|separate page]].
For a description of the current input module WBIO-AI-DV-12_4-20 mA, see [[WBIO-AI-DV-12 4-20MA/en|separate page]].
Строка 161: Строка 162:
{| class="wikitable"
{| class="wikitable"
| [[File:Jumper.png|200px|thumb|center|jumper ]]
| [[File:Jumper.png|200px|thumb|center|jumper ]]
| rowspan="2" | [[File:DV12 Razor.png|300px|thumb|right|Module with  removed cover]]
| rowspan="2" | [[File:300px-DV12_Razbor_en.png|300px|thumb|right|Module with  removed cover]]
| rowspan="2"| [[File:DV12 Plata's Peremuchkami.png|300px|thumb|right|Installing jumpers]]
| rowspan="2"| [[File:300px-DV12_Plata_S_Peremuchkami.png|300px|thumb|right|Installing jumpers]]
|-
|-
| [[File:First_latch.png|mini|thumb|center|Rear cover removal]]
| [[File:First_latch.png|mini|thumb|center|Rear cover removal]]
Строка 173: Строка 174:
'''Unlike other WBIO modules, only one instance can be connected to a single controller or interface module.'''
'''Unlike other WBIO modules, only one instance can be connected to a single controller or interface module.'''


To connect, you need to dock the WBIO-AI-DV-12 module to the right of the WIren Board controller, making sure that all the connector pins on the module get into the corresponding connector holes on the controller. Next, you should go to the web interface of the controller (read more about the web interface in [[web interface_wiren_board|relevant section]]), go to the tab ''''Configs'''' and select'''''/etc/wb-hardware.conf'''''. Next, in the drop-down list, select the module name '''''WBIO-AI-DV-12 Analog Inputs'''''.
To connect, you need to dock the WBIO-AI-DV-12 module to the right of the WIren Board controller, making sure that all the connector pins on the module get into the corresponding connector holes on the controller. Next, you should go to the web interface of the controller (read more about the web interface in [[Веб-интерфейс_Wiren_Board/en|relevant section]]), go to the tab ''''Configs'''' and select'''''/etc/wb-hardware.conf'''''. Next, in the drop-down list, select the module name '''''WBIO-AI-DV-12 Analog Inputs'''''.


{| class="wikitable"
{| class="wikitable"
Строка 235: Строка 236:
{| class="wikitable" style="text-align:center"
{| class="wikitable" style="text-align:center"
|+ Dependence of the input operation mode on the installed jumper and scaling factor
|+ Dependence of the input operation mode on the installed jumper and scaling factor
!"'The presence of the jumper"'!! 'Entry type'!! "'Mode"' || "'Value scale"'
!'''The presence of the jumper'''!! '''Entry type'''!! '''Mode''' || '''Value scale'''
|-
|-
|rowspan="2"|"'No'"
|rowspan="2"|'''No'''
|Unipolar  
|Unipolar  
|Input voltage 0 — 2.5 V
|Input voltage 0 — 2.5 V
Строка 246: Строка 247:
|0.01
|0.01
|-
|-
|rowspan="2"|"'Is'"
|rowspan="2"|'''Is'''
|-
|-
|Differential  
|Differential  
Строка 253: Строка 254:
|}
|}


<!-- Для моделей, предназначенных для измерения тока коэффициент '''scale''' должен устанавливаться в значение 0.1 -->
<!-- For models designed to measure current, the'scale' factor must be set to 0.1 -->


== Изображения и чертежи устройства ==
== Images and drawings of the device ==
{{Wbincludes:WBPicturesNoDrawing|1}}
{{Wbincludes:WBPicturesNoDrawing|1}}
<!--{{Wbincludes:WBPicturesNoDrawing|2}}-->
<!--{{Wbincludes:WBPicturesNoDrawing|2}}-->
wb_editors
14 355

правок