WB 5: Errata

Материал из Wiren Board
Версия от 20:33, 27 июня 2019; RomanKulibaba (обсуждение | вклад) (Новая страница: «====Reasons and detailed description====»)

Другие языки:


0530001: Ethernet Problems

Affected devices

Wiren Board 5 rev. 5.3


Description

Sometimes, when you turn on the Ethernet controller, it is in a non-working state. Traffic does not go in both directions, despite the presence of the link. The green light on the Ethernet connector flashes frequently.


Reasons and detailed description

The ACT led is used in the PHY to set PHY mode. Incorrect connection of the led in the circuit makes the levels setting the PHY mode random.


Workarounds

The hardware fix is to solder the R83 resistor on the back of the Board under the Ethernet connector.

The software fix is to run ifdown eth0 ; ifup eth0 or ifconfig eth0 down ; ifconfig eth0 up to reinitialize the interface.

It is recommended to use the watchdog daemon to check the network availability.


=Scheduled fix

Fixed in revisions 5.6.


0530002: the ACT led on the Ethernet connector does not work

Affected devices

Wiren Board 5 rev. 5.3, shipped after 20.03.2016


Description

The left led (ACT) on the Ethernet connector does not work.


Reasons and detailed description

See 053001 above.


Workarounds

no


=Scheduled fix

Fixed in rev. 5.6.


0530003: Undefined A4 output state

Affected devices

Wiren Board 5 rev. 5.3, 5.6, 5.6.1


Description

When the controller is turned on, the A4 output may be in the open or semi-open state. If a power supply is directly connected to the A4 terminal block (the terminal block is used as an input), a short circuit on the power supply line may occur when the controller is switched on, and the output stage of the A4 output may burn.


Reasons and detailed description

Затвор транзистора на выходе A4 неправильно подтянут.


Пути обхода

  • (предпочтительный) Не подключать БП к входам A1-A4 напрямую, подключать через резистор в 1-10кОм. С этим сопротивлением дискретный и аналоговый входы будут работать, но при этом включение транзистора (A4 или любого другого) не приведёт к выгоранию выхода.
  • Отправить устройства на гарантийный ремонт


Запланированное исправление

Запланировано к исправлению в устройствах, отгруженных после 10.2016.