Troubleshooting
= = = Not working reception ==
- Make sure the driver "sees" pulses from the receiver.
- Stop service lirc (command "service lirc stop")
root@wirenboard:~# mode2 -d /dev/lirc1
- The numbers should run when you press the buttons on the remote, if not - the problem is in the "hardware" or in the mismatch of the carrier of the remote and the receiver. You should try using a different receiver.
- Make sure that lirc can decode pulse sequences according to the configuration of the remote control:
- Run back lirc ('service lirc start')
root@wirenboard:~# irw
- Due to run lines when you press the buttons on the remote. If mode2 works and irw doesn't, there is a problem with the remote config. It is worth trying to use another config, or create a new one.