| 0 ||holding||RW||-||0-255||Channel G level, logarithmic curve | |- |1||holding||RW||-||0-255||Channel К level, logarithmic curve | |- |2 |holding |RW |- |0-255 |Channel B Level, logarithmic curve | |- |3 |holding |RW |- |0-255 |Channel W level , the logarithmic curve |WB-MRGBW-D |- | | | | | | | |- |5 |holding |RW |0 0: standard mode, 1: disable control |button operation mode | |- |6 |input |R | |1 - pressed, 0 - released |the state of the button 1 | |- |7 |input |R | |1 - pressed, 0 - released |the state of the button 2 | |- |8 |input |R | |1 - pressed, 0 - released |button status 3 (WB-MRGBW-D) | |- |9 |holding |RW |0 |freq = 24 kHz / (value + 1) (0 - 239) |PWM frequency | |- |13 |holding |RW |100 |x 10ms (2 - 500) |Time for a smooth change of the brightness during turn on and off | |- ||||||||||| | |- |32 |input |R | | |number of button 1 presses |since version 1.1.1 |- |33 |input |R | | |number of button 2 presses |since version 1.1.1 |- |34 |input |R | | |number of button 3 presses |since version 1.1.1 |- | 110 || holding || RW || 96 || baud rate / 100
( 24, 48, 96, 192, 384, 576, 1152 )|| RS-485 port speed, divided by 100
(Configure RS-485 communication parameters for Wiren Board Modbus devices) | |- | 111 || holding || RW|| 0 || 0 - no parity bit (none), 1 - odd (odd), 2 - even (even) || RS-485 port parity bit setting. | |- | 112 || holding || RW || 2 || 1 or 2 || number of stop bits of RS-485 port. | |- | 128 (0x80) || holding || RW || 1 || ||

device Modbus-address 

|all |- | 129 (0x81) || holding || RW || 0 || 0 or 1 || Go to bootloader mode |1.2.0 |- | 200-206 || input || R ||{'W','B','M','R','G','B'}