История
20 апреля 2021
Часть переводимой страницы WB-MSW v.3.
+22
FuzzyBot переименовал страницу WB-MSW v.3/en в WB-MSW v.3 Modbus Sensor/en без оставления перенаправления: Часть переводимой страницы WB-MSW v.3.
м
24 июля 2019
Новая страница: «== Images and drawings of the device == <!--{{WBPicturesNoDrawing|1}}--> {{WBPictures|1}}»
−28
Новая страница: «Back to peripheral devices list»
−36
Новая страница: «Details of the work with the module via Modbus Protocol is written in Relay Modules Modbus Management . There you can also…»
−118
Новая страница: «==Modbus Control==»
−20
Новая страница: «A list of firmware versions that support the update, as well as devices for which this feature is implemented, can be found in Firmware_Changelog/en| Firmware_C…»
−84
Новая страница: «Read more about flashing devices described in the article Download firmware to Wiren Board devices.»
−73
Новая страница: «== Device firmware update == Starting with the new firmware versions of the device, the firmware update functionality (firmware) via the Modbus Protocol is suppor…»
−287
Новая страница: «== Additional functions== '''Address change''' is broadcast (slave_id 0) team record (WRITE_SINGLE_REGISTER) to holding register with address 128 (0x80).»
−102
Новая страница: «{| class="wikitable" ! Parameter ! Value |- | Temperature | Internal sensor temperature |- | Humidity | Relative humidity percentage |- | Air Quality (VOC) | Air…»
−747
Новая страница: «600px|thumb|right|WB-MSW v.3 module controls and displays in the web interface»
−56
Новая страница: «The table lists the names of the parameters measured by the module and their values. The names of parameters that are not supported by a particular module will be…»
−127
Новая страница: «== Representation of WB-MSW v.3 in the Wiren Board web interface ==»
−29
Новая страница: «'''Warning: the sensor does not respond to smoke!'''»
−21
Новая страница: «The sensor is ready for operation 6 minutes after switching on. Prior to this, the air quality register contains an error value (0xFFFF). Approximately every 12 h…»
−162
Новая страница: «{| class="wikitable" ! Concentration (ppb) !! Level !! Compliance with hygienic standards !! Recommendations !! Exposure time limit |- | 2200 - 5500 || Dangerous…»
−681
Новая страница: «The sensor measures the total concentration of volatile organic substances in units per billion ppb (also called OLOS — see GOST R ISO 16000-9-2009). This param…»
−226
Новая страница: «Volatile organic compounds constitute the volatile substances released in the atmosphere as gases. The sensor determines the total concentration of volatile organ…»
−452
Новая страница: «== VOC sernsor ==»
−39
Новая страница: «The module uses a microphone with an amplifier and filters for correction on a scale, taking into account the peculiarities of the human ear perception of sounds…»
−226
Новая страница: «== Noise sensor ==»
−9
Новая страница: «'''LED indicators, light sensor and IR LEDs are made on one separate module, depending on the configuration when buying them may not be.'''»
−157
Новая страница: «The light sensor of the module has a filter that repeats the spectral sensitivity curve of the human eye. This allows you to measure the illumination in the suite…»
−204
Новая страница: «== Light sensor ==»
−25
Новая страница: «In non-residential premises, the IR provides control of air conditioning and heating plants. Note that IR commands are sent to all devices in sight, so you will n…»
−264
Новая страница: «The training is done once — the commands are stored in the device memory and can be played back by the Modbus command from the controller. The number of stored…»
−305
Новая страница: «Detailed description and use of the module, and a map of the registers is described in section WB-MSx_Consumer_IR_Manual/en|how to work with the IR receiver in…»
−122
Новая страница: «In WB-MSW v.3 the IR receiver for learning and 8 IR LEDs are under the lens.»
−61
Новая страница: «== IR remote emulation ==»
−17
Новая страница: «Indicators provide feedback during installation and operation. For example, the sensor may blink red when the optimum carbon dioxide concentration is exceeded. Wh…»
−278
Новая страница: «500px|thumb|right| LED operation in WB-MSW v.3 The module has two bright LEDs, green and red, illuminating the lens on the front surface…»
−584
Новая страница: «== LED lights ==»
−35
Новая страница: «File:CurrenMaxRawMotion.png|1000px|thumb|center|Correlation of motion sensor parameters, short blue segments indicate the periods of detection of the most inten…»
−188
Новая страница: «The intensity value of the movement allows you to programmatically in the rules engine to react in different ways at different thresholds.»
−93
Новая страница: «The device template contains two parameters: '''Current motion''' and '''Max Motion'''. If the motion sensor is polled quickly (several times per second), we can…»
−455
Новая страница: «The operation principleof the motion detection mechanism in the WB-MSW v.3 sensor is as follows. The module constantly receives "raw" values from the ADC to which…»
−646
Новая страница: «== Motion sensor == The module has a PIR motion sensor that detects the movement of objects at a distance of up to 8 m with a viewing angle of about 100 degrees.…»
−255
Новая страница: «The module has an indicator of operation and data exchange, which is visible in the technological hole on the bottom of the case. This indicator is not visible wh…»
−466
Новая страница: «== Indication ==»
−8
Новая страница: «==== How to open the sensor housing ==== {| border="1" cellpadding="2" cellspacing="1" | 450px|thumb|center| || File:WB-MSW3-OPEN_2…»
−346
Новая страница: «File:Installation_WB5_+wb-msw2.png|650px|thumb|center|Sample installation and connection of WB-MSW v.3 module. Screw clamps are located on the back side of the…»
−96
Новая страница: «The recommended mounting height of the sensor from the floor level is 1 — 1.6 m.»
−28
Новая страница: «The module must be operated under recommended environmental conditions.»
−77
Новая страница: «Module connection to RS-485 process is described RS-485:Физическое_подключение/en / here in detail.»
−19
Новая страница: «The screw terminal block of the module is located on its back side and is used to connect power lines (V+ and GND) and control over RS-485 (RS-485 A and B). When…»
−315
Новая страница: «For mounting the module, choose screws/screws with a head diameter of about 7 mm, if you want the module to be removable, and 9-10 mm — for permanent fixation.»
−117
Новая страница: «== Installation== The module has holes for mounting to the surface. The installation pattern for body sensor: File: Установочный_шаблон_WB-MS…»
−161
Новая страница: «== Data exchange == At the physical level, the module is connected via RS-485 interface. Modbus RTU Protocol is used to control the WB-MSW sensor. In Wirenboard D…»
−237
Новая страница: «| TH || temperature and humidity measurement |- | L || light measurement |- | I || IR transceiver |- | S || sound pressure level measurement |- | M || motion sens…»
−163