Power Meter WB-MAP12H/en: различия между версиями

Материал из Wiren Board
(Новая страница: «== Counter power supply == The WB-MAP12(H) counter can be powered from any of the connected phases. For data exchange via Modbus to the controller, you must also…»)
(Новая страница: «The stored energy values are stored when the meter is powered off.»)
Строка 111: Строка 111:
The WB-MAP12(H) counter can be powered from any of the connected phases. For data exchange via Modbus to the controller, you must also apply power to the connector the front end. It is possible to power the meter only from the interface part. In this case, the AC parameters are not measured (the voltage across all channels will be displayed as 0 V), but the current values obtained from the current transformers will be measured correctly.
The WB-MAP12(H) counter can be powered from any of the connected phases. For data exchange via Modbus to the controller, you must also apply power to the connector the front end. It is possible to power the meter only from the interface part. In this case, the AC parameters are not measured (the voltage across all channels will be displayed as 0 V), but the current values obtained from the current transformers will be measured correctly.


Накопленные значения энергии сохраняются при отключении питания счетчика.
The stored energy values are stored when the meter is powered off.


==Работа при провалах и прерываниях напряжения==
==Работа при провалах и прерываниях напряжения==

Версия 16:03, 17 июня 2019

WB-MAP12H multichannel energy meter

Purchase online Внимание: Отображаемое название «Multichannel power meter WB-MAP12H» переопределяет ранее заданное отображаемое название «Power Meter WB-MAP12H».

Purpose

WB-MAP12 is a multichannel electricity meter(meter of electrical network parameters) designed for energy management and power quality monitoring. The WB-MAP12 meter is ideal for process electricity metering in apartment buildings and office buildings, for consumer monitoring in data centers and smart offices.

The use of external plug-in current transformers allows system installation without disconnecting the energy consumers.


For active energy meter provides accuracy class 0.5 S. For reactive energy - accuracy class is 1.

Modifications

Type
WB-MAP12H Model with the measurement of the coefficients of the harmonics of current and voltage
WB-MAP12 Model without measuring current and voltage harmonics


Technical parameters

Measured parameters

For a full list of measured parameters see page Power Meter WB-MAP12H Measuring Parameters

Harmonic amplitudes and the current and total harmonic distortion factor (THD) are measured only in models with index "H".

Characteristics

Parameter value
power supply
Supply voltage 9 V — 28 V DC(interface part)

50 V — 250 V AC (measuring part)

Maximum power consumption 1.3 Вт
The average power consumption 0.9 Вт
Terminals and wire section
The recommended wire cross section with NSUI, mm2 0,75 — 1 (2,5 for power inputs)
The length of the standard NSVE sleeve, mm 8
Torque of screws, N∙m 0,2 (0,4 for power inputs)
Measurement channels
Number of channels 12 single-phase or 4 three-phase
Analyzed harmonics of voltage and current frequency 1 — 42
Control
control interface RS-485
Interface isolation Galvanically isolated from the measuring circuits
Communication protocol Modbus RTU, address is set by software, factory settings are indicated on the label
The parameters of the RS-485 interface

The default speed of 9600 bps; data bits 8; parity N; stop bits 2; the interface Parameters can be configured programmatically:

  • Speed: 1200, 2400, 4800, 9600 (default), 19200, 38400, 57600, 115200 bps
  • Data: 8 bits
  • Parity check: none(default), 1 - odd, 2 - even
  • Stop bits: 1, 2 (default)
Ready for operation after powering on 1 c
Dimensions
Dimensions 106,25 x 90,2 x 57,5 mm
Operating conditions
Air temperature -40°С to +80°С
Relative humidity up to 98%, without condensation

Meter overall dimensions

Overall dimensions

Counter power supply

The WB-MAP12(H) counter can be powered from any of the connected phases. For data exchange via Modbus to the controller, you must also apply power to the connector the front end. It is possible to power the meter only from the interface part. In this case, the AC parameters are not measured (the voltage across all channels will be displayed as 0 V), but the current values obtained from the current transformers will be measured correctly.

The stored energy values are stored when the meter is powered off.

Работа при провалах и прерываниях напряжения

Замер энергии прекращается при напряжении меньше 180 вольт (провал или прерывание напряжения), порог задается в одном из Modbus-регистров счетчика.

Обмен данными

На физическом уровне модуль подключается через интерфейс RS-485. Для управления счетчиком используется протокол Modbus RTU. В устройствах Wirenboard данные Modbus передаются по линиям связи RS-485. Подробнее смотрите страницу Протокол Modbus. Modbus-адрес счетчика задается на заводе и нанесен на наклейке. Адрес может быть изменен программно. Подробности смотрите в разделе Управление по Modbus.

WB-MAP3H Power Meter Connection

Настройка

WB-MAP CT Configuration

Индикация

Индикаторы

Счетчик имеет 5 светодиодных индикаторов:

  • S — зеленый индикатор статуса, мигает при обмене данными по Modbus
  • CF1...CF4 — красные индикаторы потребляемой суммарной энергии для каждого из трехфазных каналов (учитывается только активная энергия). Мигание индикаторов означает потребление электроэнергии: 1000 импульсов соответствуют 1 кВт·ч (в прошивке до v.2,1 - 3200 импульсов на 1 кВт·ч).

Представление в web-интерфейсе

Полный список названий параметров, отображаемых в web-интерфейсе приводится на странице Счетчик WB-MAP12H: измеряемые параметры и погрешности, их названия в веб-интерфейсе Wiren Board.

{{#invoke:Template translation|renderTranslatedTemplate|template=Template:Warning|noshift=1}}

При добавлении устройства WB-MAP12 вы можете выбрать один из нескольких шаблонов устройств:


Шаблон Модель и назначение
WB-MAP12H Основной шаблон для моделей с измерением коэффициентов гармоник тока и напряжения
WB-MAP12H (basic) Упрощенный шаблон для моделей без измерения коэффициентов гармоник тока и напряжения (нет значений AN, Ifund, N, NN, RN, NP, Pfund, Pharm, S, THD I, THD U, Total AN, Total N, Total Pfund, Total Pharm, Total RN, Total RP, Total S, Total SV, Ufund -- названия см. на странице со списком измеряемых параметров, ссылка выше).
WB-MAP12H (+ harmonics) Расширенный шаблон для моделей с измерением коэффициентов гармоник тока и напряжения (до 15 гармоники по току и до 7 гармоники по напряжению)
WB-MAP12H (+ all harmonics) Полный шаблон для моделей с измерением коэффициентов гармоник тока и напряжения (до 42 гармоники по току и по напряжению)
WB-MAP12H (basic div2) Упрощенный шаблон для моделей без измерения коэффициентов гармоник тока и напряжения с вводами, рассчитанными на токи > 65А
WB-MAP12E Шаблон для модели, поддерживающей измерения просадки тока и напряжения (модель в разработке)

Описание Modbus-регистров

Счетчик поддерживает большое количество Modbus-регистров, которые хранят значения измеряемых и вычисляемых величин, а также регистры управления счетчиком.

Таблицу регистров, описывающих измеряемые величины, можно найти на странице Таблица Modbus-регистров измеряемых и вычисляемых величин.

Таблица управляющих регистров приведена на странице Многоканальный счётчик электроэнергии WB-MAP12H: таблица управляющих Modbus-регистров.

Изображения и чертежи устройства


По ссылкам ниже вы можете скачать изображения и чертежи устройства WB-MAP12H.

Corel Draw 2018: WB-MAP12H.cdr.zip

Corel Draw PDF: WB-MAP12H.cdr.pdf

Autocad 2013 DXF: Мы еще не подготовили чертеж этого устройства. Вы можете запросить чертеж устройства "Многоканальный счётчик электроэнергии WB-MAP12H" на портале техподдержки Wiren Board (необходима регистрация).