== | == Digital inputs == | ||
=== | ===Purpose=== | ||
Connection of pulse counters, buttons, switches, sensors with "dry contact"output. | |||
=== | ===Technical parameters=== | ||
8 | 8 inputs for connection of "dry contacts" with group galvanic isolation. The scheme of inputs is shown in the figure. The terminal is supplied ~ 4.5 V, when the earth current flows a small (1mA), causing the operation of the input. | ||
{| class="wikitable" | {| class="wikitable" | ||
! | !Parameter | ||
! | !Value | ||
|- | |- | ||
| | |Number of inputs | ||
|8 | |8 | ||
|- | |- | ||
| | |Isolated input groups | ||
|1 | |1 | ||
|- | |- | ||
| | |Input type | ||
|" | |"dry contact", | ||
the opening of the current at | |||
earth short | |||
|- | |- | ||
| | |Operation condition | ||
| | |GND input lockout | ||
|- | |- | ||
| | |Tripping current | ||
|1 | |1 mA | ||
|- | |- | ||
| | |Minimum pulse width to trigger | ||
|10 ms | |10 ms | ||
|- | |- | ||
| | |Minimum time between consecutive signals | ||
|5 ms | |5 ms | ||
|- | |- | ||
| | |Voltage of "wetting" | ||
|4. | |4.5 V | ||
|} | |} | ||
=== | ===Connection=== | ||
==== | ==== Sensors/counters with pulse outputs/buttons. ==== | ||
Such devices form a signal by closing two wires that are suitable for them. Connect one wire to the GND terminal of the module. Connect the second wire to the Dx terminal. Some counters have a pulse output on the optocoupler, then the two wires have a polarity - "plus" and "minus". In this case, minus is connected to GND, plus to Dx. | |||
==== | ==== Devices with open collector output. ==== | ||
The device and the module must have a common ground. Connect the open collector output to the Dx terminal. | |||
The module inputs are galvanically isolated from the controller. Therefore, the ground GND of the module and the controller may be different. | |||
[[ | [[File:DI.png|300px|thumb|none|Digital inputs DI|link=http://contactless.ru/wiki/index.php/%D0%A4%D0%B0%D0%B9%D0%BB:DI.png]] | ||
== | == Front panel connectors == | ||
[[Файл:Netmon2 front panel photo.jpg|thumb|700px| передняя панель]] | [[Файл:Netmon2 front panel photo.jpg|thumb|700px| передняя панель]] | ||
{| class="wikitable" | {| class="wikitable" | ||
! colspan="4" rowspan="1" | | ! colspan="4" rowspan="1" |Relay outputs | ||
! colspan="1" rowspan="2" |* | ! colspan="1" rowspan="2" |* | ||
! colspan="1" rowspan="2" | | ! colspan="1" rowspan="2" |Analog inputs | ||
! colspan="1" rowspan="2" | | ! colspan="1" rowspan="2" |Second extension module | ||
! colspan="4" rowspan="2" | | ! colspan="4" rowspan="2" |Discrete inputs, dry contact type" | ||
! colspan="2" rowspan="2" | | ! colspan="2" rowspan="2" |Analog inputs | ||
! colspan="1" rowspan="2" | | ! colspan="1" rowspan="2" |Analog RX inputs | ||
! colspan="1" rowspan="2" |1- | ! colspan="1" rowspan="2" |1-Wire | ||
! colspan="1" rowspan="2" |RS-485 #1 | ! colspan="1" rowspan="2" |RS-485 #1 | ||
! colspan="1" rowspan="2" |RS-485 #2 CAN | ! colspan="1" rowspan="2" |RS-485 #2 CAN | ||
Строка 360: | Строка 360: | ||
|} | |} | ||
== | == Temperature and humidity sensor == | ||
Wiren Board NETMON-2 | Wiren Board NETMON-2 can be equipped with built-in temperature and humidity sensor. For more information, see [[Датчик AM2320/en| AM2320 sensor]]. | ||
== | ==Software== | ||
[[Программное обеспечение Wiren Board/en|Wiren Board software]] | |||
== | == Peripheral connection == | ||
See [[Wiren Board 5: Подключение периферийных устройств/en| Wiren Board 5: Connecting peripherals]] | |||